Mobile installation procedure<br />

2 Strip 10 mm (3/8”) of insulation from the stranded copper wires, push in the tension<br />

clamps with your screwdriver, insert the wires, then release the clamps. Gently tug the<br />

wires to make sure they are secure.<br />

Permanent 12V (+).<br />

Use 14 AWG wire.<br />

Negative/Return/Ground<br />

(GND)<br />

12V ignition (IGN).<br />

Use 20 AWG wire<br />

minimum to 14 AWG<br />

wire maximum.<br />

Apply pressure with<br />

screwdriver here to<br />

open pole’s tension<br />

clamp. Release<br />

pressure to close<br />

While clamp is open,<br />

insert wire here.<br />

Best practice: Use a red wire for power (+), black wire for ground (GND), and yellow wire<br />

for ignition (IGN) to be consistent with similar <strong>Genetec</strong> installations.<br />

Step B: Provide power to the LPR Processing Unit (part 2)<br />

This section shows you how to connect the SharpX power cable to the vehicle.<br />

Return to diagram, click here.<br />

Before you begin: You’ll need a 15A in-line fuse ready.<br />

IMPORTANT These instructions are not intended to replace the vehicle’s owner manual. If<br />

you are unsure about the vehicle’s internal wiring, refer to the owner manual before<br />

continuing.<br />

1 Connect the wire from the LPR Processing Unit’s + pole, through the 15A in-line fuse,<br />

to the vehicle’s 12V power source (permanent +12V).<br />

NOTE Install the fuse at the source of the vehicle’s 12V system tapping point. The LPR<br />

Processing Unit is already protected internally by an electronic circuit breaker.<br />

2 Connect the wire from the LPR Processing Unit’s GND pole to the vehicle’s chassis for<br />

grounding.<br />

3 Connect the wire from the LPR Processing Unit’s IGN pole to the vehicle’s ignition signal<br />

(+12V active when at ON/RUN key position).<br />

Step C: Connect the SharpX CAT5e cable to the LPR Processing Unit<br />

This section shows you how to connect the SharpX CAT5e cable to the LPR Processing Unit.<br />

The SharpX camera cable is an “all-in-one” cable that contains the shielded CAT5e<br />

conductor wires you need to crimp and connect to the included RJ45 plug (also shielded).<br />

genetec.com | <strong>AutoVu</strong> <strong>Handbook</strong> <strong>5.1</strong> <strong>SR2</strong> | Download latest version 99<br />