Mobile installation procedure<br />

2 Crimp the wires according to the TIA/EIA-568-B.1-2001 specification, using the T568B<br />

conductor arrangement. Remember that the cable and connector are shielded, so you<br />

need to fold the foil shield so it has contact with the RJ45’s metal shell.<br />

3 After you’ve attached the RJ45 connector, plug the CAT5e cable into the into the first<br />

Data Link port.<br />

Connect RJ45 here<br />

4 Repeat these steps for the other SharpX camera as needed.<br />

Step D: Connect the SharpX power cable to the LPR Processing Unit<br />

This section shows you how to connect the SharpX power cable to the LPR Processing Unit.<br />

NOTE SharpX connectors use push-in tension clamps to secure the wires.<br />

Return to diagram, click here.<br />

Before you begin: You’ll need a 2.5 mm flat head screwdriver.<br />

1 Attach the 5-pole connector to the camera port, then tighten the securing screws.<br />

Make sure to tighten the<br />

securing screws.<br />