LOCTITE ® ZETA ® 7735 UV WAND SYSTEMS<br />

Item Numbers: 98317A and 958216<br />

The <strong>Loctite</strong>® ZETA® 7735 UV Wand Systems utilize a 50 watt mercury arc lamp with a universal power supply. The state-of-the-art<br />

lamp with elliptical reflector and custom coating delivers unequaled spectral and optical performance in the 50 watt category.<br />

These wand systems bridge the gap between low intensity and high intensity spot curing products. They are ideally suited for the<br />

medium to low intensity requirements of the <strong>ph</strong>oto-optics and audiology industries. Other common uses are fillet curing, wire<br />

tacking, and shallow potting. The system can be operated manually or in the timed mode and is capable of interfacing with a PLC.<br />

Continuous lamp intensity monitoring is also available by selecting item 958216 and the required<br />

Light Intensity Monitor item 891494. The light guides are also sold separately from<br />

the base units. Light guide choices are highlighted below.<br />

Features:<br />

• 5 to 7 W/cm 2 UV output<br />

• 50 watt high pressure mercury arc lamp<br />

• 2,000 hours of expected UV lamp life with<br />

proper handling and maintenance<br />

• Manual or timed shutter light exposure, 0 to 99.9 seconds<br />

• Hour meter for monitoring accumulated lamp life<br />

• Selector switch for either 110 or 230 VAC<br />

Additional Features for Item 958216 when used in conjunction with 891494<br />

• LED control display highlights relative intensity<br />

changes in 10% increments<br />

• Minimum required intensity can be programmed for a warning<br />

or integrated to PLC for external alarm or shutdown condition<br />

LIGHT CURE Wand Systems<br />

Theory of Operation<br />

When the unit is switched on, the proper electrical power is immediately supplied to the lamp. It will take approximately five<br />

minutes for the lamp to reach full power. Once the lamp has reached full power, the unit is ready to cure adhesive. The operator will<br />

present the part under the end of the UV light guide. Curing will take place when the UV light is directed at the liquid adhesive.<br />

Engaging the foot switch opens the shutter and UV energy produced by the lamp is immediately transmitted through the flexible<br />

light guide. The end of the wand can be manually operated or mounted in a fixed position.<br />

Light Guides Sold Separately<br />

Descriptions<br />

983677: Single end 5 mm diameter x 1,000 mm long<br />

Light Guide<br />

983684: Dual end 3 mm diameter x 1,000 mm long<br />

Light Guide (initial purchase requires<br />

951639 – Balancing Adapter)<br />

951681: Single end 5 mm diameter x 1,500 mm long<br />

Light Guide<br />

Typical Light Guide Cure Areas<br />

983677: 1 ⁄4" to 1 ⁄2" diameter<br />

983684: 1 ⁄8" to 1 ⁄4" diameter<br />

951681: 1 ⁄4" to 1 ⁄2" diameter<br />

LOCTITE ® LIGHT INTENSITY MONITOR<br />

Item Number: 891494<br />

Power Supply<br />

Main Fuse<br />

Dimensions<br />

Weight<br />

Parts Included<br />

TECHNICAL SPECIFICATIONS<br />

90/265 VAC; 50/60 Hz input<br />

1 A, 250 V<br />

5.5" H x 6.1" W x 6.8" D<br />

1 lbs.<br />

(1) Intensity Monitor<br />

(1) Sensor Input Cable<br />

(1) Power Cord (1) Manual<br />

TECHNICAL SPECIFICATIONS<br />

Item Numbers 98317A / 958216<br />

Power Supply<br />

100/240 VAC; 50/60 Hz input<br />

Power Protection<br />

5 A / 250 V fuse<br />

Auxiliary Control Voltage<br />

12 VDC<br />

Entry Fuse<br />

3 A, 250 V<br />

Dimensions<br />

7.3" H x 11.1" W x 12.8" D<br />

Weight<br />

19.5 lbs.<br />

Optimized Spectral Output Range<br />

UVA, B, C<br />

Replacement Bulb<br />

(Item Number and Type)<br />

UV Output<br />

Characteristics<br />

Parts Included<br />

Replacement Parts<br />

Typical<br />

UV Spectral Range<br />

Primary Peak<br />

98339 – Lamp/Reflector Module<br />

50 watt HPMA UV Bulb<br />

5 to 7 W/cm 2<br />

(using 5 mm x 1,000 mm light guide)*<br />

250 to 410 nm<br />

365 nm<br />

(1) <strong>Loctite</strong> ® ZETA ® 7735 UV Wand System<br />

(1) Ultraviolet Protection Glasses (1) Line Cord<br />

(1) UV Lamp (1) Foot Pedal (1) Manual<br />

98339 – 50 watt HPMA UV Bulb<br />

Additional Accessories Sold Separately<br />

98048 –<br />

<strong>Loctite</strong> ® ZETA ®<br />

7021 Spot Radiometer<br />

(See page 114)<br />

891494 –<br />

<strong>Loctite</strong> ® Light<br />

Intensity Monitor –<br />

for 958216 only<br />

* Exact output measurement is dependent on the brand and calibration method<br />

of the UV meter, and the condition and straightness of the light guide used.<br />

For additional information and the full line of <strong>equipment</strong>, visit www.<strong>equipment</strong>.loctite.com.<br />