equipment sourcebook - Loctite.ph
equipment sourcebook - Loctite.ph
equipment sourcebook - Loctite.ph
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Valves & Pumps<br />
DISPENSING<br />
LOCTITE ® MICRO NEEDLE VALVE<br />
Item Number: 98084<br />
The <strong>Loctite</strong>® Micro Needle Valve is a pneumatically-operated, needle and seat valve that is designed<br />
for very small adhesive drops in a pressure-time dispensing system. It is precise down to 0.0005 ml,<br />
and has an adjustable stroke control to pinpoint your exact dispense requirement. This valve features<br />
the convenience to directly attach filled product syringes ranging in size from 5 to 30 ml for<br />
dispensing. Only stainless steel cannula dispense needles should be used for proper dispensing<br />
and the valve must be used in conjunction with a <strong>Loctite</strong>® brand controller, product reservoir<br />
and dispense tip, sold separately.<br />
Features:<br />
• Dispenses low to medium viscosity UV curing products down to a fraction of a microliter<br />
• Short opening stroke provides extremely fast, positive shut-off<br />
• External stroke control adjustment makes it easy for operator to fine tune shot sizes<br />
• Compact design allows for mounting flexibility and<br />
easy integration into automated applications<br />
• Capable of connecting to syringe barrels<br />
TECHNICAL SPECIFICATIONS<br />
as small as 5 ml to 30 ml<br />
Type<br />
High Precision<br />
• Change the luer fitting to a tube fitting<br />
Viscosity Range<br />
Low to Medium<br />
and any size pressure reservoir can be used<br />
Size 5" L x 1.1" D (127 mm L x 28.5 mm D)<br />
• Designed to be used with high precision<br />
Weight 8 oz. (227 g)<br />
stainless steel needles<br />
Maximum Fluid Pressure<br />
100 psi (7 bar)<br />
Theory of Operation<br />
Application of adhesive using the <strong>Loctite</strong>® Micro Needle Valve is<br />
achieved in conjunction with a pressure-time controller and<br />
adhesive reservoir system. The controller directs the pressurized<br />
air to the actuator of the valve through the inlet air port for a predetermined<br />
period of time. This causes the normally<br />
closed, needle rod assembly to retract from the seat inside the<br />
dispensing tip, allowing the adhesive to flow from the material<br />
inlet to the dispensing tip. At the end of the cycle, the controller<br />
releases the input air pressure, allowing the spring to return the<br />
needle rod back to its original closed position.<br />
NO FLOW<br />
Fluid Inlet<br />
1 ⁄8" NPT<br />
Air Inlet 10-32 UNF-2B Male Luer-Lok ®<br />
Pneumatic Supply Minimum – 60 psi (4.8 bar) Maximum – 100 psi (7 bar)<br />
Product Inlet<br />
Fluid Outlet<br />
Dispense Patterns<br />
Used to Dispense<br />
Stroke Adjustment<br />
Suck-Back<br />
Valve Type<br />
Wetted Components<br />
1 ⁄4" NPT<br />
1 ⁄4" UNF Luer-Lok ® Tip<br />
Drop, Dot, Bead<br />
Light Cure/Acrylics<br />
Yes<br />
No<br />
Pressure-Time Dispense<br />
Acetal Copolymer, Stainless Steel, PTFE<br />
Parts Included<br />
(1) Needle Variety Kit – Uses stainless steel needles only<br />
(1) Fluid Fitting, 1 ⁄8" NPT x 1 ⁄4" Tube<br />
(1) Product Feed Line, 1 ⁄4" (1) Air Line Tubing, 5 ft.<br />
(1) Micro Needle Valve (1) Manual<br />
Additional Information For Spare Parts and Accessories, see pages 84-85.<br />
For Fluid Compatibility Selector Chart, see pages 73-74.<br />
For Dispense Tips, see pages 80-81.<br />
Additional Accessories Sold Separately<br />
97123 – <strong>Loctite</strong> ®<br />
Single Channel<br />
Automatic<br />
Controller<br />
97007 / 97010 –<br />
<strong>Loctite</strong> ®<br />
Integrated<br />
Semi-Automatic<br />
Controllers<br />
97208 – <strong>Loctite</strong> ®<br />
10 ml Syringe<br />
Air Line Adapter<br />
97017 / 97020 –<br />
<strong>Loctite</strong> ® Integrated<br />
Semi-Automatic<br />
Controllers<br />
with Low<br />
Level Sensors<br />
97245 – <strong>Loctite</strong> ®<br />
30 ml Syringe<br />
Air Line Adapter<br />
982720 / 982721 / 982723 /<br />
982724 / 982726 /<br />
982727 –<br />
<strong>Loctite</strong> ®<br />
Bond-A-Matic ®<br />
Reservoirs<br />
FLOW<br />
1022006 –<br />
<strong>Loctite</strong> ® Digital<br />
Multi-Functional<br />
Controller<br />
97101 –<br />
<strong>Loctite</strong> ® Digital<br />
Dispense<br />
Controller<br />
984691 – <strong>Loctite</strong> ®<br />
Advancing<br />
Slide<br />
(2" Stroke)<br />
The RED represents the fluid path.<br />
98099 – <strong>Loctite</strong> ® Precision Filter and Regulator<br />
(required for use with all pressure-time dispense controllers, other than 97123)<br />
985281 – <strong>Loctite</strong> ® Bracket, 997569 – <strong>Loctite</strong> ® Silicone Grease<br />
66<br />
For additional information and the full line of <strong>equipment</strong>, visit www.<strong>equipment</strong>.loctite.com.