LOCTITE ® ZETA ® 7760 UV WAND SYSTEMS<br />

Item Numbers: 98450 and 958239<br />

The <strong>Loctite</strong>® ZETA® 7760 UV Wand Systems utilize a 200 watt high pressure mercury arc lamp with a universal power supply and<br />

a liquid-filled light wand. These systems have the highest intensity output for a <strong>Loctite</strong>® brand wand system by a factor of 2. The<br />

<strong>Loctite</strong>® ZETA® 7760 UV Wand Systems can be operated manually or in the timed mode and are capable of interfacing with a PLC<br />

controlled circuit. Continuous lamp intensity monitoring is also available by selecting item 958239 and the required Light<br />

Intensity Monitor item 891494. The light guides are also sold separately from the base units.<br />

Light guide choices are highlighted below.<br />

Features:<br />

• Our highest output light intensity wand. Typical initial<br />

Intensity is 16 to 20 W/cm 2<br />

• Contains a high pressure mercury arc lamp<br />

• 1,000 hours of expected UV lamp life with proper<br />

handling and maintenance<br />

• Manual or timed shutter light exposure, 0 to 99.9 seconds<br />

• Hour meter for monitoring accumulated lamp life<br />

• Self-test diagnostics displays message when a problem exists<br />

Additional Features for Item 958239 when used in conjunction with 891494<br />

• LED control display highlights relative intensity<br />

changes in 10% increments<br />

• Minimum required intensity can be programmed for a<br />

warning or integrated to PLC for external alarm or<br />

shutdown condition<br />

Theory of Operation<br />

When the unit is switched on, the proper electrical power is<br />

immediately supplied to the lamp. It will take a few minutes for<br />

the lamp to reach full power. The operator will manually<br />

or automatically place the part under the end of the UV wand.<br />

Curing will take place when the UV light is directed at the liquid<br />

adhesive. Engaging the foot switch opens the shutter and UV<br />

energy produced by the lamp is immediately transmitted<br />

through the flexible light guide. The end of the wand can be<br />

manually operated or mounted in a fixed position.<br />

Light Guide Options – UV wands<br />

Description<br />

Dimensions<br />

Item Numbers<br />

Single Pole 2 Pole 3 Pole 4 Pole<br />

Standard 1 5 mm x 1000 mm 983677 • • •<br />

3 mm x 1000 mm N/A 983684 2 98596 2 98597 2<br />

5 mm x 1500 mm 951681 • • •<br />

Enhanced UVC 2 5 mm x 1000 mm 97326 • • •<br />

3 mm x 1000 mm N/A 97328 2 98593 2 98594 2<br />

5 mm x 1500 mm 98543 • • •<br />

1. Enhanced UVC wands require optional filter kit (98598) to optimize tack-free<br />

surface cure on the <strong>Loctite</strong>® ZETA® 7760. (sold separately)<br />

2 Requires balancing adapter (951639) on initial setup.<br />

• Multi-pole guides are only available with 3 mm diameter poles.<br />

TECHNICAL SPECIFICATIONS<br />

Item Numbers 98450 / 958239<br />

Power Supply<br />

90/265 VAC; 50/60 Hz input<br />

Power Protection<br />

4 A / 250 V fuse<br />

Auxiliary Control Voltage<br />

24 VDC<br />

Lamp Life<br />

Approximately 1,000 hours<br />

Warm-Up Time<br />

5 minutes<br />

Main Fuse<br />

5 A, 250 V<br />

Dimensions<br />

8.3" H x 11.5" W x 13.4" D<br />

Weight<br />

19.5 lbs.<br />

Optimized Spectral Output Range<br />

UVA, B, C<br />

16 to 20 W/cm<br />

Typical<br />

(using 5 mm x 1,000 mm light guide)*<br />

UV Output<br />

Characteristics UV Spectral Range<br />

250 to 410 nm<br />

Primary Peak<br />

365 nm<br />

Parts Included<br />

(1) <strong>Loctite</strong> ® ZETA ® 7760 UV Wand System<br />

(1) Ultraviolet Protection Glasses (1) Power Cord<br />

(1) UV Lamp (1) Foot Pedal (1) Manual<br />

Replacement Parts<br />

98451 – 200 watt HPMA UV Bulb<br />

Additional Accessories Sold Separately<br />

98048 –<br />

<strong>Loctite</strong> ® ZETA ®<br />

7021 Spot Radiometer<br />

(See page 114)<br />

891494 –<br />

<strong>Loctite</strong> ® Light<br />

Intensity Monitor –<br />

for 958239 only<br />

* Exact output measurement is dependent on the brand and calibration method<br />

of the UV meter, and the condition and straightness of the light guide used.<br />

LIGHT CURE Wand Systems<br />

LOCTITE ® LIGHT INTENSITY MONITOR<br />

Item Number: 891494<br />

Power Supply<br />

Main Fuse<br />

Dimensions<br />

Weight<br />

Parts Included<br />

TECHNICAL SPECIFICATIONS<br />

90/265 VAC; 50/60 Hz input<br />

1 A, 250 V<br />

5.5" H x 6.1" W x 6.8" D<br />

1 lbs.<br />

(1) Intensity Monitor<br />

(1) Sensor Input Cable<br />

(1) Power Cord (1) Manual<br />

For additional information and the full line of <strong>equipment</strong>, visit www.<strong>equipment</strong>.loctite.com.<br />