FINAL SAMPLING AND ANALYSIS PLAN - Documents for Moffett Field

FINAL SAMPLING AND ANALYSIS PLAN - Documents for Moffett Field

FINAL SAMPLING AND ANALYSIS PLAN - Documents for Moffett Field

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Matrix<br />

Analytical<br />

Group<br />

Method/SOP<br />

Reference<br />

QC Sample<br />

Method Blank<br />

Table 28-4. Laboratory Quality Control Samples – Wipe/Soil/ EPA Method<br />

6010B<br />

Wipe/Soil<br />

Metals<br />

EPA 6010B<br />

Frequency/<br />

Number 1<br />

1/batch<br />

Method/SOP QC<br />

Acceptance<br />

Limits<br />

No detects ≥ ½<br />

QL<br />

LCS 1/batch 80%-120%<br />

Post-digestion<br />

Spike<br />

Serial Dilution<br />

MS/MSD<br />

(soil only)<br />

Method of<br />

Standard<br />

Addition<br />

When dilution<br />

fails<br />

1/batch<br />

75%-125%<br />

≤10% <strong>for</strong><br />

analytes with<br />

concentration<br />

>50x QL<br />

1/batch 80%-120%<br />

When matrix<br />

interference is<br />

suspected<br />

Corrective Action<br />

Reanalyze with all<br />

associated samples<br />

Reprep and<br />

reanalyze the LCS<br />

and all samples<br />

Analyze samples by<br />

method of standard<br />

of addition<br />

Per<strong>for</strong>m post<br />

digestion spike<br />

If the result is<br />

indicative of matrix<br />

interference, discuss<br />

in the case narrative.<br />

Otherwise, check <strong>for</strong><br />

a possible source of<br />

error, and<br />

extract/reanalyze the<br />

sample.<br />

Person(s)<br />

Responsible<br />

<strong>for</strong> Corrective<br />

Action<br />

Analyst<br />

Data Quality<br />

Indicator<br />

(DQI)<br />

Accuracy<br />

Measurement<br />

Per<strong>for</strong>mance<br />

Criteria<br />

No detects ≥ ½<br />

QL<br />

Analyst Accuracy 80%-120%<br />

Analyst Accuracy 75%-125%<br />

Analyst<br />

Analyst<br />

Accuracy<br />

Interferences -<br />

Accuracy/Bias<br />

- Precision<br />

≤10% <strong>for</strong><br />

analytes with<br />

concentration<br />

>50x QL<br />

80%-120%<br />

NA NA NA Interferences NA<br />

Notes:<br />

1<br />

Batch is equivalent to 20 or fewer samples prepared and analyzed together with common QC samples.<br />

Final Sampling and Analysis Plan<br />

Installation Restoration Site 29, Hangar 1<br />

Former Naval Air Station, <strong>Moffett</strong> <strong>Field</strong>, <strong>Moffett</strong> <strong>Field</strong>, Cali<strong>for</strong>nia<br />

DCN: AMEC-8816-0005-0039<br />

April 2010<br />

Page 28-4