Table 28-5. Laboratory Quality Control Samples – Soil/ EPA Method 8270B<br />

Matrix<br />

Analytical<br />

Group<br />

Method/SOP<br />

Reference<br />

QC Sample<br />

Soil<br />

SVOCs<br />

EPA 8270C<br />

Frequency/<br />

Number 1<br />

Method/SOP<br />

QC<br />

Acceptance<br />

Limits 2<br />

Method Blank 1/batch No detects ≥QL<br />

LCS<br />

1/batch<br />

Laboratory<br />

Limits<br />

(Appendix C)<br />

Lab Duplicate 1/batch ≤20% RPD<br />

Surrogate<br />

Internal<br />

Standard<br />

All<br />

environmental<br />

and laboratory<br />

samples<br />

All<br />

environmental<br />

and laboratory<br />

samples<br />

Laboratory<br />

Limits<br />

(Appendix C)<br />

50%-100%<br />

Corrective Action<br />

Reanalyze with all<br />

associated samples if<br />

there are suspect<br />

instrument per<strong>for</strong>mance<br />

or loading issues.<br />

If instrument is ok then<br />

re-prep and reanalyze<br />

samples.<br />

See note 3<br />

Reanalyze with all<br />

associated samples if<br />

there are suspect<br />

instrument per<strong>for</strong>mance<br />

or loading issues.<br />

If instrument is ok the<br />

re-prep and reanalyze<br />

samples<br />

See note 3<br />

Evaluate in<br />

consideration of other<br />

batch QC parameters<br />

and sample<br />

homogeneity. Re-prep<br />

and reanalyze if no<br />

extenuating<br />

circumstances are<br />

found. High RPD <strong>for</strong><br />

non-detects are not<br />

reanalyzed<br />

Reanalyze once to<br />

confirm matrix<br />

interference<br />

Reanalyze once to<br />

confirm matrix<br />

interference<br />

Person(s)<br />

Responsib<br />

le <strong>for</strong><br />

Corrective<br />

Action<br />

Analyst or<br />

QA<br />

Manager<br />

Analyst or<br />

QA<br />

Manager<br />

Analyst or<br />

QA<br />

Manager<br />

Analyst or<br />

QA<br />

Manager<br />

Analyst or<br />

QA<br />

Manager<br />

Data<br />

Quality<br />

Indicator<br />

(DQI)<br />

Accuracy<br />

Accuracy<br />

Precision<br />

Accuracy<br />

Measurement<br />

Per<strong>for</strong>mance<br />

Criteria<br />

No detects ≥QL<br />

Laboratory Limits<br />

(Appendix C)<br />

≤20% RPD<br />

Laboratory Limits<br />

(Appendix C)<br />

Accuracy 50%-100%<br />

Notes:<br />

1<br />

Batch is equivalent to 20 or fewer samples prepared and analyzed together with common QC samples.<br />

Final Sampling and Analysis Plan<br />

Installation Restoration Site 29, Hangar 1<br />

Former Naval Air Station, <strong>Moffett</strong> <strong>Field</strong>, <strong>Moffett</strong> <strong>Field</strong>, Cali<strong>for</strong>nia<br />

DCN: AMEC-8816-0005-0039<br />

April 2010<br />

Page 28-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!