WORKSHEET #15: REFERENCE LIMITS <strong>AND</strong> EVALUATION TABLE<br />
This worksheet identifies the project-required action limits and quantitation goals. Project<br />
Action Limits (PALs) are defined below in Tables 15-1 through 15-4.<br />
Table 15-1. Reference Limits and Evaluation <strong>for</strong> PCBs in Pre-construction<br />
Samples<br />
Matrix: Soil<br />
Analytical Group: PAHs<br />
Analyte<br />
Chemical<br />
Abstract<br />
Service<br />
(CAS)<br />
Number<br />
Project<br />
Action Limit<br />
(µg/kg)<br />
Project Action<br />
Limit<br />
Reference<br />
Project<br />
Quantitation<br />
Limit Goal 1<br />
(µg/kg)<br />
Laboratory-specific<br />
(ug/kg)<br />
QLs 1<br />
(µg/kg)<br />
Method<br />
Detection<br />
Limit 1<br />
(MDLs)<br />
(µg/kg)<br />
Aroclor 1016 12674-11-2 NE 40 CFR 761.61 2 50 10 2.7<br />
Aroclor 1221 11104-28-2 NE 40 CFR 761.61 2 50 10 5<br />
Aroclor 1232 11141-16-5 NE 40 CFR 761.61 2 50 10 1.2<br />
Aroclor 1242 53469-21-9 NE 40 CFR 761.61 2 50 10 1.6<br />
Aroclor 1248 12672-29-6 NE 40 CFR 761.61 2 50 10 1.2<br />
Aroclor 1254 11097-69-1 NE 40 CFR 761.61 2 50 10 0.78<br />
Aroclor 1260 11096-82-5 NE 40 CFR 761.61 2 50 10 2.2<br />
Aroclor 1268 11100-14-4 NE 40 CFR 761.61 2 50 10 5<br />
Total Aroclor -65 3 1,000 4 40 CFR 761.61 2 350 10 5<br />
Notes:<br />
1 Limits based on dry weight.<br />
2<br />
CFR 761.61 – self-implementing cleanup of PCB contaminated waste <strong>for</strong> high-occupancy area.<br />
3<br />
Total PCB is not registered in the CAS system. There<strong>for</strong>e, the Department of Navy assigned a number with the “-”<br />
prefix to be used <strong>for</strong> the NEDD.<br />
4 Total Arocolor will be determined by adding individual Aroclor concentrations. The laboratory will report detected<br />
concentration between MDL and QL as estimated. If an Aroclor is not detected, the MDL value will be used to<br />
determine total Arocolor concentration.<br />
Final Sampling and Analysis Plan<br />
Installation Restoration Site 29, Hangar 1<br />
Former Naval Air Station, <strong>Moffett</strong> <strong>Field</strong>, <strong>Moffett</strong> <strong>Field</strong>,<br />
Cali<strong>for</strong>nia<br />
DCN: AMEC-8816-0005-0039<br />
April 2010<br />
Page 15-1