WORKSHEET #15: REFERENCE LIMITS <strong>AND</strong> EVALUATION TABLE<br />

This worksheet identifies the project-required action limits and quantitation goals. Project<br />

Action Limits (PALs) are defined below in Tables 15-1 through 15-4.<br />

Table 15-1. Reference Limits and Evaluation <strong>for</strong> PCBs in Pre-construction<br />

Samples<br />

Matrix: Soil<br />

Analytical Group: PAHs<br />

Analyte<br />

Chemical<br />

Abstract<br />

Service<br />

(CAS)<br />

Number<br />

Project<br />

Action Limit<br />

(µg/kg)<br />

Project Action<br />

Limit<br />

Reference<br />

Project<br />

Quantitation<br />

Limit Goal 1<br />

(µg/kg)<br />

Laboratory-specific<br />

(ug/kg)<br />

QLs 1<br />

(µg/kg)<br />

Method<br />

Detection<br />

Limit 1<br />

(MDLs)<br />

(µg/kg)<br />

Aroclor 1016 12674-11-2 NE 40 CFR 761.61 2 50 10 2.7<br />

Aroclor 1221 11104-28-2 NE 40 CFR 761.61 2 50 10 5<br />

Aroclor 1232 11141-16-5 NE 40 CFR 761.61 2 50 10 1.2<br />

Aroclor 1242 53469-21-9 NE 40 CFR 761.61 2 50 10 1.6<br />

Aroclor 1248 12672-29-6 NE 40 CFR 761.61 2 50 10 1.2<br />

Aroclor 1254 11097-69-1 NE 40 CFR 761.61 2 50 10 0.78<br />

Aroclor 1260 11096-82-5 NE 40 CFR 761.61 2 50 10 2.2<br />

Aroclor 1268 11100-14-4 NE 40 CFR 761.61 2 50 10 5<br />

Total Aroclor -65 3 1,000 4 40 CFR 761.61 2 350 10 5<br />

Notes:<br />

1 Limits based on dry weight.<br />

2<br />

CFR 761.61 – self-implementing cleanup of PCB contaminated waste <strong>for</strong> high-occupancy area.<br />

3<br />

Total PCB is not registered in the CAS system. There<strong>for</strong>e, the Department of Navy assigned a number with the “-”<br />

prefix to be used <strong>for</strong> the NEDD.<br />

4 Total Arocolor will be determined by adding individual Aroclor concentrations. The laboratory will report detected<br />

concentration between MDL and QL as estimated. If an Aroclor is not detected, the MDL value will be used to<br />

determine total Arocolor concentration.<br />

Final Sampling and Analysis Plan<br />

Installation Restoration Site 29, Hangar 1<br />

Former Naval Air Station, <strong>Moffett</strong> <strong>Field</strong>, <strong>Moffett</strong> <strong>Field</strong>,<br />

Cali<strong>for</strong>nia<br />

DCN: AMEC-8816-0005-0039<br />

April 2010<br />

Page 15-1