The m<strong>in</strong>imum detectable activity (MDA) characterizes the system before perform<strong>in</strong>g any<br />
measurements, therefore it is def<strong>in</strong>ed on the basis of the detection limit. It is calculated as:<br />
equation 2.3. 13<br />
where:<br />
t M is the time of measurement;<br />
y is the yield, i.e. the probability of emission of the considered radiation per nuclear<br />
transformation;<br />
ε is the efficiency factor.<br />
In case of direct measurements of activity <strong>in</strong> organs or whole body as considered <strong>in</strong><br />
the aforementioned equations, “background” has a particular mean<strong>in</strong>g because it is a “not<br />
contam<strong>in</strong>ated subject ”. However the person’s background is determ<strong>in</strong>ed by the radionuclides<br />
that are naturally present with<strong>in</strong> body and that can significantly change from subject to<br />
subject. The MDA calculated on the basis of its background spectrum will be characteristic<br />
for such person. In order to have a more general description of MDA capability of a detect<strong>in</strong>g<br />
system, a general background spectrum is normally calculated as average of background<br />
spectra of a reference group of not contam<strong>in</strong>ated persons. The evaluations of MDA are then<br />
carried out on this average spectrum.<br />
DIN methodology is not applied to a phoswich detect<strong>in</strong>g system. For such detector the<br />
MDA is calculated by substitut<strong>in</strong>g the L D with 2 times the standard deviation of the net counts<br />
rate <strong>in</strong> the region of <strong>in</strong>terest <strong>in</strong> the spectrum [136]. The spectrum is evaluated by subtraction<br />
of four reference person’s background spectra with similar body proportions and potassium<br />
content. From the result<strong>in</strong>g differences the standard deviation is calculated.<br />
2.3.2 MATERIALS AND METHODS<br />
2.3.2.1 Description of the devices<br />
MDA = L D<br />
t Mεy<br />
The direct measurements of activity <strong>in</strong> organs and tissues were performed with both<br />
HPGe and phoswich detect<strong>in</strong>g systems. Both systems are located <strong>in</strong> a shielded room with<br />
approximately <strong>in</strong>ner dimensions: height 2.25 m; width 2.25 m; lenght 4.20 m. The room is<br />
accessible through a pneumatically moved steel door and shielded with four different layers.<br />
In decreas<strong>in</strong>g order of Z they are: Steel (15 cm), Lead (3 mm), T<strong>in</strong> (1.5 mm) and Copper (0.5<br />
mm). The room is also equipped with a double ventilation system operat<strong>in</strong>g at 292 cm 3 h -1 and