three detectors are used. Two detectors are located on both side of subject’s head: <strong>in</strong> Figure<br />

2.3.10 they are depicted accord<strong>in</strong>g to a lateral prospective. The third detector is located under<br />

the subject’s head and therefore not visible.<br />

Both detect<strong>in</strong>g systems were calibrated, for their own measurement positions, us<strong>in</strong>g<br />

the whole USTUR phantom to evaluate the efficiency factors <strong>in</strong> case of activity distribution <strong>in</strong><br />

the skeleton. Furthermore both detect<strong>in</strong>g systems were calibrated us<strong>in</strong>g LLNL phantom to<br />

evaluate the efficiency factor <strong>in</strong> case of activity distribution <strong>in</strong> lungs, liver and lymph nodes.<br />

For such calibration issue, efficiency factors relat<strong>in</strong>g to different chest wall thickness were<br />

evaluated us<strong>in</strong>g the different overlays available for the LLNL phantom.<br />

As phoswich is even used for measurement of activity <strong>in</strong> head, efficiency factors for<br />

activity distribution <strong>in</strong> lungs, liver and lymph nodes were evaluated us<strong>in</strong>g the LLNL phantom<br />

to evaluate their contribution for measurements performed on head. In this case, ow<strong>in</strong>g to<br />

their low contributions, only a LLNL phantom overlay was used (29 mm, one of the two<br />

central values).<br />

The efficiency factors of the detect<strong>in</strong>g systems for 59.5 keV energy peak of 241 Am are<br />

given <strong>in</strong> Table 2.3.3 and Table 2.3.4 under different measurements positions of detectors<br />

(MP) and activity distribution (AD) of the radionuclide <strong>in</strong> the body. For LLNL phantom<br />

efficiency factors relate to overlays with 50%/50% fat/muscle ratio.<br />

HPGe<br />

Measurement position<br />

1 2<br />

Figure 2.3.10 The measurement positions (MP) of HPGe and phoswich detectors <strong>in</strong> respect<br />

of the subject.<br />

64<br />

Phoswich<br />

Measurement position<br />

Head Lungs Liver Knee