Warnings / MessagesImportant Messages Meaning MeasuresV-Angle not suitable forcalibration (Check V-angleor face) !Calibration result out oftolerance. Previous valuesretained !Hz-Angle out of limit !Measurement Error. Tryagain.Aiming tolerance not met or telescope position/facenot changed.Computed values out of tolerance.Previous values retained.Hz-angle in second face/telescope pos.deviates more than 5 gon from the targetpoint.Measurement error appeared (e.g. instableset up or period between measuring in telescopeposition I and II too long).Aim on the target point with an accuracy ofmin. 5 gon. The target point must beapproximately in the horizontal plane.Confirmation of the message required.Repeat measurements.Confirmation of the message required.Aim on the target point with an accuracy ofmin. 5 gon.Confirmation of the message required.Repeat the process.Confirmation of the message required.<strong>TPS400</strong>-5.0.1en110 Calibrations