Data TransferWith this special function measured data can be transferredvia the serial interface to a receiver (e.g. aLaptop). Using this type of transfer the success of thetransfer is not checked.Job: Selection of job from which data shouldbe transferred.Data: Select the data range to be transferred(measurements, fixed points)Format: Select output format. Select <strong>Leica</strong>-GSIformat,or your own format created inthe "Format Manager" and transfer tothe LGO/LGO-Tools.[SEND] Starts the transmission.Example:Within the "data" setting "MEASUREMENTS" a dataset could be shown as follows:11....+00000D19 21..022+1664182622..022+09635023 31..00+0000664958..16+00000344 81..00+0000334282..00-00005736 83..00+0000009187..10+00001700If the receiver is to slow in processing datathedata could be lost. With this type of data transferthe instrument is not informed about the performanceof the receiver (no protocol).GSI-ID’s11 PtID21 Horizontal direction22 Vertical angle25 Orientation31 Slope distance32 Horizontal distance33 Height difference41-49 Codes and attributes51 ppm [mm]58 Prism constants81-83 (E, N, H) Target point84-86 (E, N, H) Stand point87 Reflector height88 Instrument height<strong>TPS400</strong>-5.0.1en112 Data Transfer