11.07.2015 Views

Leica TPS400 Series User Manual

Leica TPS400 Series User Manual

Leica TPS400 Series User Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

EDMmeasuringprogramStandard**AccuracyTime permeasurement0 - 500 m 2 mm + 2 ppm typ. 3 - 6 s> 500 m 4 mm + 2 ppm max. 12 sTracking*** 5 mm + 3 ppm typ. 0.25 s** Standard deviation acc. to ISO 17123-4, beaminterruptions, severe heat shimmer and movingobjects within the beam path can result in deviationsof the specified accuracy.*** Accuracy and measure time depend on atmosphericconditions, target object and observationsituation.Distance measurement RL-prism (with reflector)• Range of measurement: ..........from 1000m up• Display unambiguous: ....................... to 12 kmUltra & Power: Range (with reflector)AtmosphericconditionsStandardprismReflector tape60 x 601 2200 m (7200 ft) 600 m (2000 ft)2 7500 m (24600 ft) 1000 m (3300 ft)3 > 10000 m (33000 ft) 1300 m (4200 ft)1) Strong haze, visibility 5km; or strong sunlight,severe heat shimmer2) Light haze, visibility about 20km; or moderatesunlight, slight heat shimmer3) Overcast, no haze, visibility about 40km; noheat shimmer<strong>TPS400</strong>-5.0.1en148 Technical Data