TroubleshootingDisplayedEvent CodeDescription Cause TroubleshootingSystem Event/Error Codes - Yellow LEDE004 DEFAULT VALUES <strong>Analyzer</strong> has been reset or is new outof boxCalibrate the analyzerE021 HARDWARE FAULT System error Contact Technical Support 1-800-225-1480E101 CH1 TEMP OUT OF RANGE Temperature sensor on channel 1 out ofrange (5 °C to 45 °C) for ISEE102 CH2 TEMP OUT OF RANGE Temperature sensor on channel 2 out ofrange (5 °C to 45 °C) for ISEE111 CH1 CAL DUE User calibration required on channel 1.No calibration has been performed inuser specified time interval.E112 CH2 CAL DUE User calibration required on channel 2.No calibration has been performed inuser specified time interval.E127 CH1 SOUT mA OVER RANGE Measured sensor value above Sout highlimit value on channel 1E128 CH1 SOUT mA UNDER RANGE Measured sensor value below Sout lowlimit value on channel 1E129 CH1 TOUT mA OVER RANGE Measured temperature value above Touthigh limit value on channel 1E130 CH1 TOUT mA UNDER RANGE Measured temperature value below Toutlow limit value on channel 1E131 CH2 SOUT mA OVER RANGE Measured sensor value above Sout highlimit value on channel 2E132 CH2 SOUT mA UNDER RANGE Measured sensor value below Sout lowlimit value on channel 2E133 CH2 TOUT mA OVER RANGE Measured temperature value above Touthigh limit value on channel 2E134 CH2 TOUT mA UNDER RANGE Measured temperature value below Toutlow limit value on channel 2Check ATC cable and probe connections. Replace if needed.Check ATC cable and probe connections. Replace if needed.Recalibrate the analyzer.Recalibrate the analyzer.Verify user selectable Sout high limit value in setup modeVerify user selectable Sout low limit value in setup modeVerify user selectable Tout high limit value in setup modeVerify user selectable Tout low limit value in setup modeVerify user selectable Sout high limit value in setup modeVerify user selectable Sout low limit value in setup modeVerify user selectable Tout high limit value in setup modeVerify user selectable Tout low limit value in setup mode<strong>Thermo</strong> <strong>Scientific</strong> <strong>Orion</strong> <strong>2110XP</strong> <strong>Ammonia</strong> <strong>Analyzer</strong> User GuideVI-15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!