Controllers and softwareR360 SafetyControllerAnalogue, digital, diagnostic and pulse inputsDigital, PWM or current-controlled outputs, H-bridge function (to IEC 61508 / EN 13849)Inputs /outputstotalInputsdigital /analogueInputs dig. /frequency(pos.)Inputsdigital(pos. / neg.)InputsdigitalOutputsdigital / PWM /curr.-controlledOutputsdigitalOutputsdigitalPWMFunctionH-bridgeWiringdiagramno.40 8 8 8 4 8 12 4 2 5 1 CR702024 8 8 – 4 8 – – – 6 1 CR750580 16 16 16 8 16 24 8 4 5 2 CR7200Drawingno.Orderno.DialoguemodulesGeneralinformationList of articlesI/O modulesMobilecontrollersApplication exampleBlock diagramDiagnosisand serviceV BBSV BBR5V3.3 VresetwatchdogSensorsfor mobileapplicationsV BBOCommon technical data55-pole connectiondigital OUTanalogue INdigital INTESTRS 232CAN 1CAN 216-bitμControllerRAM2x128kbytesFRAM32 kbytesFlash2048 kbytesclockaddressdecoderSignalconvertersConnectiontechnologyAccessoriesHousing: metalConnection: 55-pole AMP connectorTemperature range: -40...75 °CProtection rating: IP 67Ub: 10...32 V DCSwitching current outputs: 4 A / 2 AInterfaces: 2 x CAN 2.0, 1 x RS-232Program memory: 768 kB flashData memory: 128 kB SRAM, 128 kB flashData memory (non volatile): 17 kBCE, e1, appr. for railway applic. (EN 50155)Technicalinformationand customerserviceYou can find scale drawings from page 18045