<strong>XNX</strong> <strong>Universal</strong> <strong>Transmitter</strong><strong>XNX</strong> Part Number Series<strong>XNX</strong> Certifications by Part Number Series(Approvals received or Pending - Contact HA for Availability)<strong>XNX</strong>-AMSI-*****<strong>XNX</strong>-AMAI-*****<strong>XNX</strong> <strong>Transmitter</strong>IR Personality<strong>XNX</strong>-AMSV-***** / <strong>XNX</strong>-AMAV-*****<strong>XNX</strong> <strong>Transmitter</strong> mV Personality<strong>XNX</strong>-AMSE-***** / <strong>XNX</strong>-AMAE-*****<strong>XNX</strong> <strong>Transmitter</strong> EC PersonalityWith Generic 20 mA InputWith Optima PlusWith Searchline ExcelMPD-AMCB1 (Cat Bead)MPD-AMIV1 (IR Methane)MPD-AMIF1 (IR Flam)MPD-AMIC1 (IR CO 2)With 705 HTWith SensepointWith Sensepoint PPMWith Sensepoint HTWith Oxygen CartrdigeEXAMDEKRA GmbHWith H 2S Low CartridgeWith H 2S Med CartridgeWith H 2S High CartridgeWith CO CartridgeSO 2, NH 3, Cl 2, ClO 2, NO,NO 2, H 2PPM HCL, HCN,HF, O 3, PH 3Modbus ®RelaysLocal HART ®PerformanceIEC 60079-29-1EN 60079-29-1M M M M N/A N/A N/A N/A M N/A M N/A N/A N/A N/A N/A N/A N/A N/A MEN 61779-4:2000EN 45544:2000 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A M M N/A N/A N/A MEN 50104:1999 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A M N/A N/A N/A N/A N/A N/A N/A MEN 50271 B B B N/A N/A N/A N/A B B B B B B B B B B B BTUVRhinelandFunctional and Software SafetyIEC61508 B B B N/A N/A N/A N/A B B B B B B B B B N/A N/A N/AEN 50402 B B B N/A N/A N/A N/A B B B B B B B B B N/A N/A N/AATEX QANIIEex QARBASEEFAIEC 13980 2002* applies to EC adapters onlyM N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A M* M* M* M* M* M* N/A N/A N/ALegend: M = M25 threaded <strong>Transmitter</strong>s & Adapters B = Both 3/4 NPT and M25 N/A = Not Approved or Not ApplicableSection 6 - Specifications 6-136.2 <strong>XNX</strong> Certifications by Part Number Series
RR<strong>XNX</strong> <strong>Universal</strong> <strong>Transmitter</strong>6.2.1 <strong>XNX</strong> LabelsUL Certification LabelsAn explanation of the information on the <strong>XNX</strong> certification label is shown below.<strong>XNX</strong> Unit Serial NumberProduct Name<strong>XNX</strong> Unit Part NumberMinimum Voltage Requirement(16 for EC/mV and 18 for IR)Wattage Requirement<strong>XNX</strong>UNIVERSALTRANSMITTERWARNING: • TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERE CONDUIT RUNS MUST HAVE A SEAL FITTING CONNECTED WITHIN 18" [457mm] OF ENCLOSURE.CAUTION: • FOR SAFETY REASONS THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY. READ AND UNDERSTAND MANUAL PRIOR TOSERVICING. • HIGH OFF SCALE READING MAY INDICATE EXPLOSIVE CONCENTRATIONS.• THIS AREA MUST BE FREE OF FLAMMABLE GASES DURING CALIBRATION.AVERTISSEMENT: • POUR REDUIRE LE RISQUE D' ALLUMAGE DANS L'ATMOSPHÈRE. LES CONDUITS DOIVENT AVOIR UN JOINT D'ÉTANCHÉITÉ INSTALLÉS À MOINS DEATTENTION: 18 " [457 mm] DU BOITIER.• POUR DES RAISONS DE SECURITÉ, CET EQUIPMENT DOIT ETRE UTILISÉ, ENTRETENU ET REPARÉ UNIQUEMENT PAR UN PERSONNEL QUALIFIÉ SEULEMENT.LIRE ET COMPRENDRE LE MANUEL D'INSTRUCTIONS AVANT UTILISATION.• DES LECTURES HORS ECHELLE PEUVENT INDIQUER DES CONCENTRATIONS EXPLOSIVES• CETTE ZONE DOIT ETRE EXEMPTE DE GAZ INFLAMMABLES PENDANT L'ETALONNAGEProduct NameUser Warnings/CautionsAdditional Agency Approval(configuration dependantSee <strong>XNX</strong> Certificationsby Part Number Series)<strong>XNX</strong>- SN: to 32 VDC Max. Class 2 Supply Req'd<strong>XNX</strong> <strong>Universal</strong> <strong>Transmitter</strong> for use in Class I, Div. 1 Groups B,C & DClass 1, Zone 1, Groups IIB+H2 Haz Loc. Tamb °C to °C Temp Code T4Only as to Explosion, Fire, Electrical and Shock HazardWhen Installed Per <strong>XNX</strong> ManualRelay Option <strong>XNX</strong> - UT -R or <strong>XNX</strong>-RLYContact Ratings: 250 VAC 5A, 24VDC 5A Resistive Loads Only35YLMfg'd by: Honeywell Analytics, Inc., 405 Barclay Blvd. Lincolnshire, IL 60069 USAUL ApprovalsFigure 6-1. <strong>XNX</strong> Label for Non-IS Applications<strong>XNX</strong> Unit Serial Number<strong>XNX</strong> Unit Part NumberCLASSIFIEDManufacturers Name and Address<strong>XNX</strong>UNIVERSALTRANSMITTERMinimum Voltage Requirement(16 for EC/mV and 18 for IR)Wattage Requirement<strong>XNX</strong>UNIVERSALTRANSMITTERWARNING: • TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERE CONDUIT RUNS MUST HAVE A SEAL FITTING CONNECTED WITHIN 18" [457mm] OF ENCLOSURECAUTION: • SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY.• FOR SAFETY REASONS THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY. READ AND UNDERSTAND MANUAL PRIOR TO SERVICING• HIGH OFF SCALE READING MAY INDICATE EXPLOSIVE CONCENTRATIONS.• THIS AREA MUST BE FREE OF FLAMMABLE GASES DURING CALIBRATION.AVERTISSEMENT: • POUR REDUIRE LE RISQUE D' ALLUMAGE DANS L'ATMOSPHÈRE. LES CONDUITS DOIVENT AVOIR UN JOINT D'ÉTANCHÉITÉ INSTALLÉS À MOINS DE 18 " [457 mm] DU BOITIERATTENTION: • LA SUBSTITUTION DES COMPOSANTES PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÉQUÉ.• POUR DES RAISONS DE SECURITÉ, CET EQUIPMENT DOIT ETRE UTILISÉ, ENTRETENU ET REPARÉ UNIQUEMENT PAR UN PERSONNELQUALIFIÉ SEULEMENT LIRE ET COMPRENDRE LE MANUEL D'INSTRUCTIONS AVANT UTILISATION • DES LECTURES HORS ECHELLE PEUVENT INDIQUER DESCONCENTRATIONS EXPLOSIVES • CETTE ZONE DOIT ETRE EXEMPTE DE GAZ INFLAMMABLES PENDANT L'ETALONNAGE<strong>XNX</strong>- SN: to 32 VDC Max. Class 2 Supply Req'd<strong>XNX</strong> <strong>Universal</strong> <strong>Transmitter</strong> for use in Class I, Div. 1 Groups B,C & D [Exia]Class 1, Zone 1, Groups IIB+H2 Haz Loc. Tamb °C to °C Temp Code T4Only as to Explosion, Fire, Electrical Shock Hazard and Intrinsic SafetyAssociated Apparatus Providing Intrinsically Safe Circuits When Installed Per<strong>XNX</strong> Manual and Control Drawing 1226E0402 Um=250VRelay Option <strong>XNX</strong> - UT -R or <strong>XNX</strong>-RLYContact Ratings: 250 VAC 5A, 24VDC 5A Resistive Loads Only35YLMfg'd by: Honeywell Analytics, Inc., 405 Barclay Blvd. Lincolnshire, IL 60069 USACLASSIFIED<strong>XNX</strong>UNIVERSALTRANSMITTERUser Warnings/CautionsAdditional Agency Approval(configuration dependantSee <strong>XNX</strong> Certificationsby Part Number Series)UL ApprovalsFigure 6-2. <strong>XNX</strong> Label for IS ApplicationsManufacturers Name and AddressSection 6 - Specifications 6-146.2.1 <strong>XNX</strong> Labels