12.07.2015 Views

XNX Universal Transmitter - Merkantile

XNX Universal Transmitter - Merkantile

XNX Universal Transmitter - Merkantile

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>XNX</strong> <strong>Universal</strong> <strong>Transmitter</strong>The General Status Screen provides a visual indication of the statusof the <strong>XNX</strong>. Warnings, faults, alarm levels and current concentrationlevels are displayed continuously.Status IndicatorCurrent Concentration Level(Bar Graph)Current Concentration Level(Numeric)Concentration UnitsFull ScaleAlarm 2 Set PointAlarm 1 Set PointFigure 1-10. General Status Screen - Normal Operating ModeThe Normal Operating Mode icon gives visual indication of properoperation. The <strong>XNX</strong> display also shows the concentration level of thetarget gas in two different ways. The first, found in the upper right cornerof the display, shows a numeric value in the units selected (ppm, ppb,%LEL, %VOL). The second concentration display is shown in the formof a bar graph representing the current concentration against full scaleand in relation to the defined alarm levels (for more information onsetting range and alarm levels, see Range and Alarms).When a warning is triggered, the Warning icon appears andinformation is displayed on the General Status Screen. The informationdisplayed includes the gas concentration and the warning code (seeSection 5 - Warnings/Faults for more warning code information).Warning IconWarning CodeFigure 1-11. General Status Warning DetailIf the fault icon is displayed, a fault condition has been triggered andthe display will alternate the display of the target gas concentrationand the fault code (see Section 5 - Warnings/Faults for more faultcode information).Fault IconFault CodeFigure 1-12. General Status Fault DetailWhen an alarm icon is displayed, the target gas concentrationexceeds one or both preset alarm levels, the General Status Screendisplays the gas concentration and alarm level exceeded.Alarm IconAlarm Level TriggeredTarget GasConcentrationFigure 1-13. General Status Alarm DetailIn an overrange condition, the alarm icon will display but the target gasconcentration bar graph and alarm setpoints will flash, see illustration below.Alarm Level TriggeredFull ScaleConcentrationConcentration Bar, Alarm Setpoints FlashFigure 1-14. General Status Overrange DetailIn addition to the graphic Alarm, Fault and Warning indicators, the LEDson the front panel will flash in a pattern based on the condition:ConditionAlarm 1Alarm 2WarningFaultHealthLEDRed Green YellowSolidFlashingFlashingSolidFlashingSection 1 - Introduction 1-81.4 The <strong>XNX</strong> Front Panel

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!