<strong>XNX</strong> <strong>Universal</strong> <strong>Transmitter</strong>WarningNumber Description Event History Information Condition RecoveryW016W018W019W020W021W022Installation Not CompletedECmV N/A N/AIR Excel IR Sensor Fault CodeGeneral DiagnosticECmV All PersonalitiesSee Data Field In Event List For InformationIRInternal Power Supply DefectECmV N/A N/AIR Excel IR Sensor Fault CodeForced mA TimeoutECmVIRAll PersonalitiesForce Relay TimeoutECmVIRAll Personalities15min15minmV Sensor Calibration NeededEC N/A N/AmV mV Personality Board NoneIR N/A N/AExcel sensor has not completed a 'full'installation procedure5V power supply failure in Excel receiver<strong>XNX</strong> left in force mA mode too long<strong>XNX</strong> in force relay mode too longThe mV sensor is different than currentconfiguration; a change in target gas; change insensor type. Calibrate before use.Check Excel alignment and confirm operatingdistance, rerun 'installation procedure'Remove and return to Honeywell for repair.Exit Force mA mode. See Force mA Output.Exit Force Relay mode. See Force Relays.After adjusting configuration, reset alarms andfaults.Section 5 - Warnings/Faults 5-55.3 Warning Messages