12.07.2015 Views

XNX Universal Transmitter - Merkantile

XNX Universal Transmitter - Merkantile

XNX Universal Transmitter - Merkantile

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>XNX</strong> <strong>Universal</strong> <strong>Transmitter</strong>Modbus HoldingRegister AddressDatatype Variable Name Description40007 uint8 iMonitoringState This has the following meanings:0123456789101112131415161718192021-255reservednormal monitoringin warm-uplong-term inhibitalarm simulationfault simulationLoop current stimulatedin warning MFltin Instrument Fltin beam blockin bump testshort-term inhibitperforming zero calibrationperforming span calibrationin pre-zero calibrationin pre-span calibrationin post-zero calibration, successfulin post-span calibration, successfulin post-zero calibration, failedin post-span calibration, failedin align Excel modefor future expansion40008 int16 iHeartBeat This Heartbeat is provided to facilitate detection of communications problems in programming environments where the transport-layercommunication error information is unavailable. This increments approximately every 5 seconds.It is the responsibility of the system integrator to notify plant personnel if a Modbus master fails to communicate with the <strong>XNX</strong>. Thisregister can facilitate this notification.40009 to 40010 float32 fSensorLifeDays This indicates the time remaining before the ECC sensor must be calibrated or replaced.Appendix B - Modbus ® Protocol B-4B.2 Modbus Registers