12.07.2015 Views

XNX Universal Transmitter - Merkantile

XNX Universal Transmitter - Merkantile

XNX Universal Transmitter - Merkantile

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>XNX</strong> <strong>Universal</strong> <strong>Transmitter</strong>6.3 Ordering Information6.3.1 <strong>XNX</strong> <strong>Universal</strong> <strong>Transmitter</strong>The <strong>XNX</strong> part numbering system contains all necessary information to convey the product configuration including options. Agency, Port Thread,Enclosure Material, Sensor Personality define the standard unit. Three option fields are used to define optional Relay or Fieldbus interfacesand factory installed local HART ® . The Sensor and Range field is used exclusively by mV units to assemble the defined MPD sensor typeto the <strong>Transmitter</strong> with corresponding thread. Agency approvals of the MPD are unique by device and part number. Ensure the approvals ofboth the transmitter and MPD meet the requirements of the installation.Agency Approval Port Threads Enclosure Sensor Interface Option Local HART MPD Type Installed<strong>XNX</strong> - q q q q - q q q q qATEX - AM25 - M(ATEX/IECEx Only)Stainless - S Electrochem - E None - N None - N None - NNNUL / CSA - U3/4” NPT - T(UL/CSA Only)Aluminum - A Infrared - I Relay - R Local HART ® - H MPD-** (Catalytic Bead %LEL) - CB1INMETRO - B milliVolt - V Modbus ® - M MPD-**IF1 (IR %LEL Flam) - IF1MPD-**IV1 (IR CH4 0-5% Vol) - IV1**Indicates Agency Approval and Port Thread specificationMPD-**IC1 (IR CO 20-5% Vol) - IC16.3.2 <strong>XNX</strong> EC Replacement Sensors<strong>XNX</strong>IDTarget GasCartridgePart NoMaximumRangeSelectableRangeIncrementDefaultRangeCal Gas RangeCal Gas P/NCal GasDescription1 O 2Oxygen <strong>XNX</strong>XS01SS 25.0 %Vol N/A N/A 25.0 %Vol 20.9 %Vol N/A N/A2 H 2S Hydrogen Sulfide (Low Low Range) <strong>XNX</strong>XSH3SS 15.0 ppm N/A N/A 15.0 ppm 5.0 to 10.0 ppm GFV263 10 ppm H 2S3 H 2S Hydrogen Sulfide (Low Range) <strong>XNX</strong>XSH1SS 50.0 ppm 10.0 to 50.0 ppm 0.1 ppm 15.0 ppm 3 to 35 ppm GFV258 25 ppm H 2S4 H 2S Hydrogen Sulfide (High Range) <strong>XNX</strong>XSH2SS 500 ppm 50 to 500 ppm 10 ppm 100 ppm 15 to 350 ppm GFV421 50 ppm H 2S5 CO Carbon Monoxide <strong>XNX</strong>XSC1SS 1,000 ppm 100 to 1,000 ppm 100 ppm 300 ppm 30 to 200 ppm GFV295 100 ppm CO6 SO 2Sulfur Dioxide (Low Range) <strong>XNX</strong>XSS1SS 20.0 ppm 5.0 to 20.0 ppm 5.0 ppm 15.0 ppm 2 to 14 ppm Contact HA 7.5 ppm SO 27 SO 2Sulfur Dioxide (High Range) <strong>XNX</strong>XSS2SS 50.0 ppm 20.0 to 50.0 ppm 10 ppm 50.0 ppm 6 to 35 ppm GFV441 25 ppm SO 28 NH 3Ammonia (Low Range) <strong>XNX</strong>XSA1SS 200 ppm 50 to 200 ppm 50 ppm 200 ppm 150 to 140 ppm Contact HA 100 ppm NH 39 NH 3Ammonia (High Range) <strong>XNX</strong>XSA2SS 1000 ppm 200 to 1,000 ppm 50 ppm 1,000 ppm 60 to 700 ppm Contact HA 300 ppm NH 3Section 6 - Specifications 6-16 6.3 Ordering Information

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!