02.12.2012 Views

analysis of the influences of solar radiation and façade glazing ...

analysis of the influences of solar radiation and façade glazing ...

analysis of the influences of solar radiation and façade glazing ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Appendix 2 126<br />

Construction,<br />

FLOOR, !- Name<br />

Mineral_daub, !- Outside Layer<br />

I03 100mm insulation board, !- Layer 2<br />

concrete_0_20, !- Layer 3<br />

I03 80mm insulation board, !- Layer 4<br />

concrete_0_05, !- Layer 5<br />

F17 Carpet; !- Layer 6<br />

Construction,<br />

CEILING, !- Name<br />

F17 Carpet, !- Outside Layer<br />

concrete_0_05, !- Layer 2<br />

I03 80mm insulation board, !- Layer 3<br />

concrete_0_20, !- Layer 4<br />

Mineral_daub; !- Layer 5<br />

Construction,<br />

INTRNAL-MASS, !- Name<br />

silicate_brick_0_12; !- Outside Layer<br />

Construction,<br />

DOOR-IN, !- Name<br />

Wood door - 35mm; !- Outside Layer<br />

Construction,<br />

ROOF, !- Name<br />

Mineral_daub, !- Outside Layer<br />

concrete_0_05, !- Layer 2<br />

I05 350mm insulation board, !- Layer 3<br />

concrete_0_20, !- Layer 4<br />

Mineral_daub; !- Layer 5<br />

Construction,<br />

WALL-OUT, !- Name<br />

Mineral_daub, !- Outside Layer<br />

Poroton_0_30, !- Layer 2<br />

Mineral_fiber_0_02, !- Layer 3<br />

Poroton_0_24, !- Layer 4<br />

Stucco; !- Layer 5<br />

Construction,<br />

Screen_O-Dbl Clr 3mm/13mm Arg, !- Name<br />

BRIGHT ALUMINUM SCREEN, !- Outside Layer<br />

COAT 3MM, !- Layer 2<br />

XENON 12_7MM, !- Layer 3<br />

CLEAR 3MM, !- Layer 4<br />

XENON 12_7MM, !- Layer 5<br />

CLEAR 3MM; !- Layer 6<br />

Construction,<br />

Screen_L-Dbl Clr 3mm/13mm Arg, !- Name<br />

BRIGHT ALUMINUM SCREEN, !- Outside Layer<br />

COAT 3MM, !- Layer 2<br />

XENON 12_7MM, !- Layer 3<br />

CLEAR 3MM; !- Layer 4<br />

Construction,<br />

Shade_O-Dbl Clr 3mm/13mm Arg, !- Name<br />

COAT 3MM, !- Outside Layer<br />

XENON 12_7MM, !- Layer 2<br />

CLEAR 3MM, !- Layer 3<br />

XENON 12_7MM, !- Layer 4<br />

CLEAR 3MM, !- Layer 5<br />

HIGH REFLECT - LOW TRANS SHADE; !- Layer 6<br />

Construction,<br />

Shade_L-Dbl Clr 3mm/13mm Arg, !- Name<br />

COAT 3MM, !- Outside Layer<br />

XENON 12_7MM, !- Layer 2<br />

CLEAR 3MM, !- Layer 3<br />

HIGH REFLECT - LOW TRANS SHADE; !- Layer 4<br />

!- == ALL OBJECTS IN CLASS: CONSTRUCTION WITH INTERNAL<br />

SOURCE ==<br />

Construction:InternalSource,<br />

Slab Floor with Radiant, !- Name<br />

4, !- Source Present After Layer Number<br />

4, !- Temperature Calculation Requested After Layer Number<br />

1, !- Dimensions for <strong>the</strong> CTF Calculation<br />

0.15, !- Tube Spacing {m}<br />

Mineral_daub, !- Outside Layer<br />

concrete_0_12, !- Layer 2<br />

I02 50mm insulation board, !- Layer 3<br />

concrete_0_05, !- Layer 4<br />

Terracotta; !- Layer 5<br />

!- == ALL OBJECTS IN CLASS: ZONE ==<br />

Zone,<br />

EG1, !- Name<br />

, !- Direction <strong>of</strong> Relative North {deg}<br />

0, !- X Origin {m}<br />

0, !- Y Origin {m}<br />

0, !- Z Origin {m}<br />

1, !- Type<br />

1, !- Multiplier<br />

0, !- Ceiling Height {m}<br />

0, !- Volume {m3}<br />

, !- Zone Inside Convection Algorithm<br />

, !- Zone Outside Convection Algorithm<br />

Yes; !- Part <strong>of</strong> Total Floor Area<br />

Zone,<br />

EG2, !- Name<br />

, !- Direction <strong>of</strong> Relative North {deg}<br />

0, !- X Origin {m}<br />

0, !- Y Origin {m}<br />

0, !- Z Origin {m}<br />

1, !- Type<br />

1, !- Multiplier<br />

0, !- Ceiling Height {m}<br />

0, !- Volume {m3}<br />

, !- Zone Inside Convection Algorithm<br />

, !- Zone Outside Convection Algorithm<br />

Yes; !- Part <strong>of</strong> Total Floor Area<br />

Zone,<br />

EG3, !- Name<br />

, !- Direction <strong>of</strong> Relative North {deg}<br />

0, !- X Origin {m}<br />

0, !- Y Origin {m}<br />

0, !- Z Origin {m}<br />

1, !- Type<br />

1, !- Multiplier<br />

0, !- Ceiling Height {m}<br />

0, !- Volume {m3}<br />

, !- Zone Inside Convection Algorithm<br />

, !- Zone Outside Convection Algorithm<br />

Yes; !- Part <strong>of</strong> Total Floor Area<br />

Zone,<br />

EG4, !- Name<br />

, !- Direction <strong>of</strong> Relative North {deg}<br />

0, !- X Origin {m}<br />

0, !- Y Origin {m}<br />

0, !- Z Origin {m}<br />

1, !- Type<br />

1, !- Multiplier<br />

0, !- Ceiling Height {m}<br />

0, !- Volume {m3}<br />

, !- Zone Inside Convection Algorithm<br />

, !- Zone Outside Convection Algorithm<br />

Yes; !- Part <strong>of</strong> Total Floor Area<br />

Zone,<br />

EG6, !- Name<br />

, !- Direction <strong>of</strong> Relative North {deg}<br />

0, !- X Origin {m}<br />

0, !- Y Origin {m}<br />

0, !- Z Origin {m}<br />

1, !- Type<br />

1, !- Multiplier<br />

0, !- Ceiling Height {m}<br />

0, !- Volume {m3}

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!