Appendix 2 137<br />

281, !- Lighting Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0.2, !- Return Air Fraction<br />

0.59, !- Fraction Radiant<br />

0.2, !- Fraction Visible<br />

0, !- Fraction Replaceable<br />

GeneralLights; !- End-Use Subcategory<br />

Lights,<br />

EG4 Lights 1, !- Name<br />

EG4, !- Zone Name<br />

LIGHTS-1, !- Schedule Name<br />

LightingLevel, !- Design Level Calculation Method<br />

271, !- Lighting Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0.2, !- Return Air Fraction<br />

0.59, !- Fraction Radiant<br />

0.2, !- Fraction Visible<br />

0, !- Fraction Replaceable<br />

GeneralLights; !- End-Use Subcategory<br />

Lights,<br />

EG6 Lights 1, !- Name<br />

EG6, !- Zone Name<br />

LIGHTS-1, !- Schedule Name<br />

LightingLevel, !- Design Level Calculation Method<br />

151, !- Lighting Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0.2, !- Return Air Fraction<br />

0.59, !- Fraction Radiant<br />

0.2, !- Fraction Visible<br />

0, !- Fraction Replaceable<br />

GeneralLights; !- End-Use Subcategory<br />

Lights,<br />

COR Lights 1, !- Name<br />

COR, !- Zone Name<br />

LIGHTS-1, !- Schedule Name<br />

LightingLevel, !- Design Level Calculation Method<br />

301, !- Lighting Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0.2, !- Return Air Fraction<br />

0.59, !- Fraction Radiant<br />

0.2, !- Fraction Visible<br />

0, !- Fraction Replaceable<br />

GeneralLights; !- End-Use Subcategory<br />

!- == ALL OBJECTS IN CLASS: ELECTRIC EQUIPMENT ==<br />

ElectricEquipment,<br />

OG1 ElecEq 1, !- Name<br />

OG1, !- Zone Name<br />

EQUIP-1, !- Schedule Name<br />

EquipmentLevel, !- Design Level Calculation Method<br />

350.001, !- Design Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0, !- Fraction Latent<br />

0.3000000, !- Fraction Radiant<br />

0; !- Fraction Lost<br />

ElectricEquipment,<br />

OG2 ElecEq 1, !- Name<br />

OG2, !- Zone Name<br />

EQUIP-1, !- Schedule Name<br />

EquipmentLevel, !- Design Level Calculation Method<br />

280.001, !- Design Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0, !- Fraction Latent<br />

0.3000000, !- Fraction Radiant<br />

0; !- Fraction Lost<br />

ElectricEquipment,<br />

OG3 ElecEq 1, !- Name<br />

OG3, !- Zone Name<br />

EQUIP-1, !- Schedule Name<br />

EquipmentLevel, !- Design Level Calculation Method<br />

300.001, !- Design Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0, !- Fraction Latent<br />

0.3000000, !- Fraction Radiant<br />

0; !- Fraction Lost<br />

ElectricEquipment,<br />

OG4 ElecEq 1, !- Name<br />

OG4, !- Zone Name<br />

EQUIP-1, !- Schedule Name<br />

EquipmentLevel, !- Design Level Calculation Method<br />

300.001, !- Design Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0, !- Fraction Latent<br />

0.3000000, !- Fraction Radiant<br />

0; !- Fraction Lost<br />

ElectricEquipment,<br />

EG1 ElecEq 1, !- Name<br />

EG1, !- Zone Name<br />

EQUIP-1, !- Schedule Name<br />

EquipmentLevel, !- Design Level Calculation Method<br />

350.001, !- Design Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0, !- Fraction Latent<br />

0.3000000, !- Fraction Radiant<br />

0; !- Fraction Lost<br />

ElectricEquipment,<br />

EG2 ElecEq 1, !- Name<br />

EG2, !- Zone Name<br />

EQUIP-1, !- Schedule Name<br />

EquipmentLevel, !- Design Level Calculation Method<br />

280.001, !- Design Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0, !- Fraction Latent<br />

0.3000000, !- Fraction Radiant<br />

0; !- Fraction Lost<br />

ElectricEquipment,<br />

EG3 ElecEq 1, !- Name<br />

EG3, !- Zone Name<br />

EQUIP-1, !- Schedule Name<br />

EquipmentLevel, !- Design Level Calculation Method<br />

300.001, !- Design Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0, !- Fraction Latent<br />

0.3000000, !- Fraction Radiant<br />

0; !- Fraction Lost<br />

ElectricEquipment,<br />

EG4 ElecEq 1, !- Name<br />

EG4, !- Zone Name<br />

EQUIP-1, !- Schedule Name<br />

EquipmentLevel, !- Design Level Calculation Method<br />

300.001, !- Design Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}<br />

, !- Watts per Person {W/person}<br />

0, !- Fraction Latent<br />

0.3000000, !- Fraction Radiant<br />

0; !- Fraction Lost<br />

ElectricEquipment,<br />

DG1 ElecEq 1, !- Name<br />

OG1, !- Zone Name<br />

EQUIP-1, !- Schedule Name<br />

EquipmentLevel, !- Design Level Calculation Method<br />

350.001, !- Design Level {W}<br />

, !- Watts per Zone Floor Area {W/m2}