3.1 Building description 53<br />

Fig. 3.4: POROTON-T9.<br />

A detailed characteristic <strong>of</strong> <strong>the</strong>se two types <strong>of</strong> bricks is presented in Table 3.1.<br />

Type<br />

POROTON BLOCK-T<br />

24,0-1,2<br />

POROTON-T9-30,0<br />

Table 3.1: Properties <strong>of</strong> Wienerberger hollow-bricks.<br />

Dimensions<br />

L×W×H<br />

[cm]<br />

Weight <strong>of</strong><br />

one brick<br />

[kg]<br />

Density<br />

[kg/m 3 ]<br />

37.3×24.0×23.8 21.5 1009.12<br />

24.8×30.0×24.9 12.1 653.15<br />

The steady-state temperature measurements (described in <strong>the</strong> previous chapter) were used<br />

to determine <strong>the</strong> <strong>the</strong>rmal resistance <strong>and</strong> <strong>the</strong> equivalent heat conductivity <strong>of</strong> <strong>the</strong> POROTON-<br />

T9-30,0 brick. The results <strong>of</strong> <strong>the</strong> three temperature differences between <strong>the</strong> brick sides are<br />

summarized in Table 3.2.<br />

Table 3.2: Thermal properties <strong>of</strong> <strong>the</strong> POROTON-T9.<br />

θh – θc<br />

Rb<br />

[m 2 K/W]<br />

keq<br />

[W/mK]<br />

20 3.29 0.0912<br />

30 3.11 0.0965<br />

40 3.36 0.0893