3.4 Testing <strong>of</strong> a building indoor environment during <strong>the</strong> warm period 85<br />

Based on <strong>the</strong> results <strong>of</strong> <strong>the</strong> simulation we can affirm that:<br />

• Intensive cooling with outside air at night, protection facade shields <strong>and</strong> window<br />

shades located on <strong>the</strong> internal side do not secure <strong>the</strong>rmal comfort during more than<br />

half <strong>of</strong> <strong>the</strong> warm period,<br />

• The window shade with <strong>the</strong> high reflection surface mounted outside <strong>and</strong> near <strong>the</strong><br />

fenestration guarantees <strong>the</strong> best protection <strong>of</strong> gains resulting from <strong>solar</strong> <strong>radiation</strong><br />

during <strong>the</strong> summer.<br />

First <strong>of</strong> all, <strong>the</strong> relatively high inside operate air temperature is <strong>the</strong> result <strong>of</strong> a large<br />

fenestration area <strong>of</strong> each segment <strong>and</strong> also <strong>of</strong> internal heat gains. Apart from that, <strong>the</strong> high<br />

<strong>the</strong>rmal insulation <strong>of</strong> <strong>the</strong> windows limits heat transfer when <strong>the</strong> outside air temperature is<br />

lower than <strong>the</strong> inside temperature. We can observe <strong>the</strong> lowest level <strong>of</strong> <strong>the</strong>rmal comfort in<br />

apartments OG2 <strong>and</strong> OG3. The PMV index reaches about 3 in June <strong>and</strong> September.<br />

Comparatively good conditions <strong>of</strong> comfort are present in segments OG1 <strong>and</strong> OG4. Due to<br />

effective external shading devices <strong>and</strong> night cooling, <strong>the</strong> internal air temperature stays<br />

below 28°C.<br />

The next simulations were conducted to compare <strong>the</strong> designed fenestration area with <strong>the</strong><br />

optimal windows area in summer conditions. Results <strong>of</strong> <strong>the</strong> <strong>analysis</strong> are presented in <strong>the</strong><br />

figures below.