three years after the specified warranty. During such three year period themanufacturer shall repair, modify or replace the air diffusers in a manneracceptable to the Owner, if the operation of the air diffusers is unsatisfactory.Normal wear or malfunctions due to neglect or abuse will not be consideredjustifiable reasons for unsatisfactory operation. In the event the Ownerdetermines the operation of the air diffusers to be unsatisfactory during thisthree year period and the manufacturer fails to correct the deficiencies withinsix months from the time the manufacturer is first notified in writing that suchdeficiencies exist, the Owner will, as its sole option, make the necessary repairsor replacement and deduct costs from the aforementioned bond of themanufacturer.R: No change will be made to the documents.33. Q: (SA) Section 44 45 16.02 - Page 6 (1.07A) - We recommend specifying theminimum quantity of Spare Parts. Our recommendations are below:ItemQuantityCompletely Assembled Diffusers 10Air distribution pipe support assemblies 10Air distribution pipe joints 10Tool sets, it required, from removal and 3replacement of diffuser assembliesR: Revised per Addendum No. 8.34. Q: (SA) Section 44 45 16.02 - Page 8 - 2.06 A - We recommend deleting the lastsentence and replacing with the following: "Supports shall be fabricated fromminimum " rod and shall be mounted to the floor with a single anchor bolt."R: This is added as an option per Addendum No. 8.QUESTIONS AND RESPONSES NO. 51 Q: (WGH) Requesting approval of the following equipment. We represent:1. Pick Heaters for sludge heating, Pick Heaters, PCD www.pickheaters.com2. KWI International for DAP, Sand Filters www.kwi-intl.com3. Hoffland Environmental for Filter Press, Claifiers www.hoffland.net4. Kufferath for Solid/Liquid Separation, Screw press www.kufferath.com5. Atlas Minerals and Chemicals for Tile, Grouts, Mortars, Linings, Anchor-LokLining System, Chempruf Lining System for Chemical Containment andConcrete Protection from Corrosion, www.atlasmin.omR: No additional manufacturers will be added to the specifications.2. Q: (AP) Requesting that Addison-Parrish (Luminare Package) be listed as anacceptable manufacturer for this project.R: No additional manufacturers will be added to the specifications.3. Q: (AG) On sheet 07-S-5 the note says to apply the liner to all interior surfaces ofthe wetwell. Does this include the floor as well as the walls?05/16/08 02001-158A OR 5-6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!