Yamy Power Systems:Quotation # O8RAS-027-01Austell, GA s18iB4. . Project: North Oconee WWTP770,941.2424 tel Date Issued: 5-14-08770941.2411 fax877,278,6235 tal free Expiration: 12-3-08 (P.O. for Release)wwYanceyPower.com Page # 2 of 14Under volts, Over volts, Under frequency, Over frequency, Overcurrent, Reverse Power, 6 spare faultchannels, 20 Event fault tog (name of event, engine hours at first occurrence of event, time stamp at first,occurrence, engine hours at latest occurrence of event, time stamp at latest occurrence, number, ofoccurrences of event) -# Controls: 2 LED status indicators (1 red shutdown, I amber warning), Run key and LED Indicator, Auto key andLED indicator, Stop key and LED indicator, Lamp test key, Alarm acknowledge key, Menu navigation keys,Engine and AC metering shortcut keys, All control module keys have tactile feedback, Lock down emergency stoppush button* Other features Real time clock, Service interval counter, spare discrete input/output package+ 1/0 module for customer use..LUBE SYSTEM+ Crankcase breathers, two, top mounted, 2 inch OD outlet* Oil cooler* Oil filler and dipstick, RH* Oil filter, RH* Oil pump; gear type* Shallow ill pan* Oil pan drain valve and oil sampling valve# Initial oil illMOUNTING SYSTEM* Rails, engine generator radiator mounting.* Vibration isolators mounted between generator and sub-base.PROTECTION SYSTEM* Safety shlutoff protection, electricalSTARTING SYSTEM* Two (2), 24 volt heavy duty, electric starting motors* Two (2) sets of Nicad batteries with battery rack and cables.+ Two (2) Automatic, dual rate, battery chargers, 20 amps.WEATHERPROOF ENCLOSURE* Weatherproof enclosure - Sound Attenuated (65 dbA@ 20'), fuel tank base mounted with lifting eyes* Personnel doors. Doors are 36" x 70" aluminum double panel entrance doors with weatherproofing gasket, driprail and stainless steel hardware with lockable handles and panic hardware.* Enclosure electrical accessories are pre-wired and shipped loose for connection by customer.* One (1) 45 kVA, 3 phase, 480-120/240 volt transformer with fuse disconnect* Load center 100 amp, 480-1201208.volt A.C. three (3) phase with main breaker and branch breakers for all A.C.Interior items prm-wired.* One (1) 150 amp lighting panel,* Spring open, Motorized closed, intake louvers prm-wired to load center.* 120 V.A+C. dual tube, flourescent lights with globe and guard and 2 light twitches.* 120 V.D.C. incahdescent lights With globes and guards with timer switch* One (1) Duplex GI receptacle.* Internally mounted exhaust silencer.* Ventillation fan, with thermostat, for air exhaust when the genset is not running* Stairs and common walkway with metal railings.CAT SWITCHGEAR Using POWERLYNX 3000Switchaear controls (3) Generator(sI2 - Master Control section with touch screen2 - Generator Breaker(s)2 - Utility Main Breaker(s)2 - Tie Breaker(s)6 - Distribution Breaker(s)1 - Provision for Generator Breaker. Controls included.
-k 0Quotation # O8RAS-027-01Yancey Power System259 Lee Ioduitrial d. Project:North Oconee WWTPAustell, GA 30187406770.941.2424 td Date Issued: 5-14-08770.941.2411 fax, D877.278.6236 toll free Expiration: 12-3-08 (P.O. for Release)www.YanceyPower.com Page # 3 of 142 - Provision for Distribution Breaker(s) Controls included.Detailed as follows:CATERPILLAR SWITCHGEAR POWER ASSEMBLYI Eaton MVA 15 kV Lineup Medium Voltage assemblies, 12470V, 3-Phase, 3-WIre, 60 Hertz, 500 MVA, 18 kA,NEMA 1 Indoor, UL MVSTRUCTURE 1 - CELL, 15KV 1200 A1 Rear door padlock provisions1 Hinged rear doors.1, Hinge Panel door wI ISO-Standard Cutouts1. Lightning arrester intermediate class 12 kV -,Set of 31 Surge capacitor 3-phase, 7.5 kVCOMPARTMENT A -. (3) VOLTAGE TRANSFORMER 15 KVCOMPARTMENT D - BREAKER COMPARTMENT 150 VCP-W 500 1200AI Common Fuse protection for motor, close, and trip ckts3. CT, single ratio, standard accuracySTRUCTURE 2 - CELL, 15KV 1200 A1 Rear door padlock provisions1 Hinged rear doorsCOMPARTMENT B - PROVISION FOR FUTURE BREAKER 15 KV 1200A1 Common Fuse protection for motor, close, and trip ckts3 CT, single ratio, standard accuracyCOMPARTMENT D - BREAKER COMPARTMENT 150 VCP-W 500 1200A1 Common Fuse protection for motor, close, and trip ckts3 CT, single ratio, standard accuracySTRUCTURE 3 -CELL, 15KV 1200 A1 Rear door padlock provisions1 Hinged rear doorsCOMPARTMENT B - BREAKER COMPARTMENT 150 VCP-W 500 1200A1 Common Fuse protection for motor, close, and trip ckts3 CT, single ratio, standard accuracyCOMPARTMENT D - BREAKER COMPARTMENT 150 VCP-W 500 1200A1 Common Fuse protection for motor, close, and trip ckts3 CT, single ratio, standard accuracySTRUCTURE 4 -CELL, 15KV 1200 A1 Rear door padlock provisions1 Hinged rear doors1 Upper Sectionalizing Bus 1200ACOMPARTMENT B - BREAKER COMPARTMENT 150 VCP-W 500 1200AI Common Fuse protection for motor, close, and trip ckts3 CT, single ratio, standard accuracyCOMPARTMENT C - (2) VOLTAGE TRANSFORMER 15 KVCOMPARTMENT.D - (2) VOLTAGE TRANSFORMER 15 KVSTRUCTURE 5 -CELL, 15KV 1200 A1 Rear door padlock provisions1 Hinged rear doors
- Page 1 and 2:
ADDENDUM XDATE: May 19, 2008TO:FROM
- Page 3 and 4:
( 0ORO t'The Unified Government of
- Page 5 and 6:
R: No change to bid date.3- Q: (AG)
- Page 7 and 8:
Part IGeneralSection 01 57 00Enviro
- Page 9 and 10:
005700-3Environmental and Property
- Page 11 and 12:
JORDANJONES &SGOULDINGList of Planh
- Page 13 and 14:
List of Planholders, Athens North O
- Page 15 and 16:
RADDENDUM IXDATE: May 16, 2008TO:FR
- Page 17 and 18:
AGREEMENT BETWEENBUYER AND SELLERFO
- Page 19 and 20:
* Delete page 00520-5 and replace w
- Page 21 and 22:
otherwise.F. Should either party re
- Page 23 and 24:
4gas well as construction of the la
- Page 25 and 26:
QUESTIONS AND RESPONSES NO. 5NORTH
- Page 27 and 28:
Also on drawing 05-CD-1 typical roa
- Page 29 and 30: R: No change will be made to the do
- Page 31 and 32: R: Apply protective liner to all in
- Page 33 and 34: 16. Q: (AS)Section 0421.13 - Page 5
- Page 35 and 36: induction motor data sheet.a) Is th
- Page 37 and 38: conduit size for P39 to be 1-1/2".
- Page 39 and 40: R: No change will be made to the do
- Page 41 and 42: (TC)(TDC)(TDH)(TF)(TI)(TJL)(WGH)(WS
- Page 43 and 44: (1)Section 00 41 00BidTO:UNIFIED GO
- Page 45 and 46: 004100-3Bidf. Utility Location Allo
- Page 47 and 48: 004100-5BidIte No Decito Qty uni Un
- Page 49 and 50: 0041 00-7BidIte No. Decito t.UiSUi
- Page 51 and 52: 004100-9BidMAJOR PRODUCT OR SYSTEM
- Page 53 and 54: 0041 00-11BidThe Bidder agrees here
- Page 55 and 56: EQUIPMENT ALLOWANCE SCOPE OF WORKRE
- Page 57 and 58: March 7, 2008 Amended May 13, 2008T
- Page 59 and 60: System Controls:Not included in thi
- Page 61 and 62: * No performance and laboratory tes
- Page 63 and 64: C. Seller is familiar with and is s
- Page 65 and 66: Project: Athens, GA North Oconee Ma
- Page 67 and 68: ARTICLE 4 -BASIS OF PROPOSAL4.01 Pr
- Page 69 and 70: Weir Specialty PumpsP.O. Box209 (84
- Page 71 and 72: ATHENS, GA 7 NORTH OCONEE May 12,20
- Page 73 and 74: Weir Specialty PumpsWEiRco PUMPWEMI
- Page 75 and 76: 1635W. Walnut StreetTU R B LEX Spri
- Page 77 and 78: B. $ 33,658.00 The Seller's monthly
- Page 79: Quotation # 08RAS-027-01Yancey Powe
- Page 83 and 84: Quotation # OBRAS-027-01Yaney Power
- Page 85 and 86: - Quotation # O8RAS-027-01Yaney pow
- Page 87 and 88: Quotation #- OSRAS-027-01' Yancey25
- Page 89 and 90: Quotation # 08RAS-027-01Yancey Povw
- Page 91 and 92: NPMwerSystms.259 I.eeilndustrW Bilv
- Page 93 and 94: Dubin, GregFrom:Sent:To:Cc:Subject:
- Page 95 and 96: SUPPLEMENTARY CONDITIONS (Rev. 1)Th
- Page 97 and 98: SC 15: Add the followtng paragraph:
- Page 99 and 100: 0 0 0C3) cm C C Ccm 0ES 20 ESw'-a m
- Page 101 and 102: U) SL ct )0 nm 0UCV 0 LC,9 . Q o1 f
- Page 103 and 104: QUESTIONS AND RESPONSES NO. 4NORTH
- Page 105 and 106: would the OCP policy not be enough
- Page 107 and 108: properties used in it methods allow
- Page 109 and 110: 12. Q: (TC) SECTION 31 23 60 - 5 ME
- Page 111 and 112: R: Refer to 05-CU drawings and Spec
- Page 113 and 114: R: See subsequent addenda.Zone 2 84
- Page 115 and 116: actually a refractor 545 or if a re
- Page 117 and 118: ~vRk0 oRADDENDUM IIDATE: April 15,
- Page 119 and 120: STANDARDGENERAL CONDITIONSOF THECON
- Page 121 and 122: GENERAL CONDITIONSARTICLE 1 - DEFIN
- Page 123 and 124: 29. Notice to Proceed--A written no
- Page 125 and 126: within the Contract Time, or extend
- Page 127 and 128: others as appropriate will be held
- Page 129 and 130: 3.04 Amending and Supplementing Con
- Page 131 and 132:
a. reviewing and checking all such
- Page 133 and 134:
Documents. CONTRACTOR shall also fu
- Page 135 and 136:
5. allow for partial utilization of
- Page 137 and 138:
ARTICLE 6 - CONTRACTOR'S RESPONSIBI
- Page 139 and 140:
substitte item will perform adequat
- Page 141 and 142:
permits and licenses. CONTRACTOR sh
- Page 143 and 144:
esponse to such an emergency, a Wor
- Page 145 and 146:
1. is attributable to bodily injury
- Page 147 and 148:
8-05 Lands andEasements; Reports an
- Page 149 and 150:
accordance with the provisions of p
- Page 151 and 152:
such Claim, dispute, or other matte
- Page 153 and 154:
equipment brought to the Project if
- Page 155 and 156:
the ENGINEER and the other party to
- Page 157 and 158:
incorporation in the Work. Such ins
- Page 159 and 160:
ARTICLE 14 - PAYMENTS TO CONTRACTOR
- Page 161 and 162:
2. Should CONTRACTOR neglect to pay
- Page 163 and 164:
14.07 Final Payment ENGINEER will r
- Page 165 and 166:
Documents in connection with uncomp
- Page 167 and 168:
ADDENDUM VillDATE: May 15, 2008TO:F
- Page 169 and 170:
tRkzZRDrawings1. Delete Sheet 05-SE
- Page 171 and 172:
Copyright C 2 000National Society o
- Page 173 and 174:
AGREEMENT... THIS AGREEMENTi betwee
- Page 175 and 176:
6.04 Seller and Buyer shall execute
- Page 177 and 178:
D. The Contract Documents may only
- Page 179 and 180:
ATTACHMENT ASnecificationsSection T
- Page 181 and 182:
PROPOSAL FORMPRESELECTED EQUIPMENT
- Page 183 and 184:
ARTICLE 4 - BASIS OF PROPOSAL4.01 P
- Page 185 and 186:
PARKSON CORPORATIONUnanimous Writte
- Page 187 and 188:
Hanson, RickFrom:MAHONEY770@aol.com
- Page 189 and 190:
Furt-her,.p ease advise me ifyou wi
- Page 191 and 192:
Copyright 02000National Society of
- Page 193 and 194:
AGREEMENTTHIS AGREEMENT is between(
- Page 195 and 196:
6.04 Seller and Buyer shalt execute
- Page 197 and 198:
ARTICLE 11 - MISCELLANEOUS11.01 Def
- Page 199 and 200:
ATTACHMENT ASpecificationsSection T
- Page 201 and 202:
SIEMENSCOST PROPOSALOdor Control (B
- Page 203 and 204:
SIEMENSTABLE OF CONTENTSNo.Item Des
- Page 205 and 206:
ARTICLE 1- PROPOSAL RECIPIENT1.01 T
- Page 207 and 208:
6,02 The following documents are in
- Page 209 and 210:
SIEMENSSECTION 2SIEMENS' DETAILED S
- Page 211 and 212:
SIEMENSTransfbrmer, Circuit breaker