20.08.2015 Views

Subcontractors

ADDENDUM X

ADDENDUM X

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

HiQuotation # 08RAS-027-01Yancey Power Systems . ... ... . .. .269 Lee ]ndutr l BlvdAustell, GA 3016&7406Project: North Oconee WWTP770.941.2424 tel770.941.2411 tax Date Issued: 5-14-08.877.278,6235 toll free: Expiration: 12-3-08 (P.O. for Release)wwwYanceyPower.com ... . Page of.14 .o System Metering Screen with graphical presentation of all functions.6 System Settings Screen.o Generator Control Screen for each generatoro Generator Metering Screen for each generator with graphical presentation of. all functionsspecified.o Generator Settings Screen.. I0 Generator Demand Priority Control and Status Screen ..... . .o Generator Load Shed Control Screen.o Engine Monitoring (Engine Meter/Gauge) Screen for each generator that shall contain agraphical representation of all of the engine gauges and data specifiedI* Generator Engine Air I Cool Screen.* Generator Engine Oil / Fuel Screen.* Utility Control Screen for each Utility Main.* Utility Metering Screen that shall contain graphical representations of all the electrical meteringfunctions specified.* Utility Setting Screen that shall contain all of the adjustments specified.* Annunciator Menu Screeno System Annunciation Screen that shall contain all of the Status, Lamp Test and Alarm pointsspecified.o Generator Annunciator Screen for each generator that shall contain: Status, Lamp Test, Pre-Alarms and Shutdown faults specified,o Utility Annunciation Screen that shall contain all of the Status, Lamp Test and Alarm pointsspecified.* Report Menu Screeno Generator Settings Report Screeno Utility Settings Report Screen*o Plant Test Settings Report ScreenPassword Entry screen that shall contain a numeric keypad for password entry.* Alarm Summary Screen that shall contain a time/date stamped System Alarm Summary." Trending Screenso System Trend ScreenooGenerator Trending ScreenEngine Historical Trending Screen* Tie Control Screen for each Controlled Tie breaker* Tie Metering ScreenHIGH RELIABILITY FEATURES:* 24 Vdc Best Source DC System* "instant Auto" Selector SwitchADDITIONAL ITEMS:I - Standard Eaton Electrical Breaker Accessory kit1 - 24 Vdc Sealed Battery, Rack & Charger (shipped loose for contractor to install, assemble, and connect atjobsite)I - 125 Vdc Battery System, Rack & Charger (shipped loose for contractor to install, assemble, and connect atjobsite)- Battery cells are: Flooded NiCad- Charger: Solid State SCR controlled, Regulated and filtered DC output, LCD Display2 - NGR (Neutral Grounding Resistor) Nema 3R, 15kV System, 10 sec., 100/200A, 8.3kVw/ CT - Donut style (600V), Bar type (Line Voltage rated)2 - Operations &Maintenance Manual provided after site startup is complete (additional copies and/or CD can beprovided at additional cost)6- Submittal binders & 2 CD copy of submittal package (additional copies can provided at additional cost)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!