20.08.2015 Views

Subcontractors

ADDENDUM X

ADDENDUM X

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Quotation # 08RAS-027-01Yancey Povwer Systges259 Lee Industrial Blvd.Austell, GA 30168748Project: North Oconee WWTP770.941.2424 tel770.941.2411 fax bate.I.s.ed. 5-14-08877,27&86235 toll freeExpiration: 12-3-08 (P.O.. for Release)www.YsnceyPowe.com Pag # 11 of 14All Materials, equipment and services proposed comply with all the Drawings andSpecifications included in or with the Request for Proposal, except as follows:1. Spec secton 263213 .13-3, i..03.G "Transient response for a step load meets the loading requirementsspecifled. Transient:response for a single block load load application will be 35% votage dip with recovery inless than 6 seconds.2; Spec section 263213.13-12, 2,05.5,6 & 7 - Alternatot frame size is a2770 with a temperature rise of 105degrees C at 40 degree C ambient. Alternator is limited to a 60% non-linear load at the Prime rating of200OkW and 65% non-linear load at the standby rating of 2250kW. Transient response for a block loadapplication will be 35% voltage dip with recovery in less than 6 seconds.3. Spec section 263213,13-15, 2.06B. - Control panel selector is a pushbutton not a toggle switch.4. Spec section 263213.13-25, 2,07.B2.o - Synchronizer is a Caterpillar synchronizer not a Woodward.5. Spec section 263213.13-32, 2,13.H - Enclosure stairs are to be manufactured by the approved Packagingvendor, not Thompson.6. Spec section 263213.13-34, 2.15 & 2.16- Some of the spare parts listed are not applicable. Spare parts kitwill be limited to that identified in the proposal.7. Spec section 263213.13-36, 3.03.C - Factory testing of the gensets will be separate from the switchgear.8. The 125VDC batteries and battery charger supplied for the PowerLynx ® system breaker controls will beshipped loose for the contractor to install at the jobsite. One 50A 208VAC 3 phase dedicated emergencycircuit (per charger) will be required to be furnished by others to the charger.9. We are supplying one breaker test cabinet per section 2.1610. All meters and switches, except test switches, not shown In drawing 32-E-4 will be shown on thetouchscreens mentioned above.11. Generator sets are not IBC rated. Therefore, we take exception to any reference as related to gensets.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!