SERVOPACKs<br />

Σ-7S Single-axis FT83 SERVOPACKs SGM7D Motor Drive with built-in INDEXER<br />

Item<br />

Fixed<br />

Input<br />

Continued from previous page.<br />

Specification<br />

Allowable voltage range: 5 VDC ±5%<br />

Number of input points: 1<br />

SEN (Absolute Data Request) signal<br />

Number of input points: 1<br />

Input method: Line driver or open collector<br />

Input Signals<br />

• /DEC (Origin Return Deceleration Switch) signal<br />

• /RGRT (Registration Input) signal<br />

• CLR (Clear) signal<br />

Allowable voltage range: 24 VDC ±20%<br />

Number of input points: 7<br />

Input method: Sink inputs or source inputs<br />

Input Signals<br />

• /S-ON (Servo ON) signal<br />

• /P-CON (Proportional Control) Signal<br />

• P-OT (Forward Drive Prohibit) and N-OT (Reverse Drive<br />

Prohibit) signals<br />

• /ALM-RST (Alarm Reset) signal<br />

• /P-CL (Forward External Torque Limit) and /N-CL (Reverse<br />

External Torque Limit) signals<br />

• /SPD-D (Motor Direction) signal<br />

• /SPD-A and /SPD-B (Internal Set Speed Selection) signals<br />

• /C-SEL (Control Selection) signal<br />

• /ZCLAMP (Zero Clamping) signal<br />

• /INHIBIT (Reference Pulse Inhibit) signal<br />

• /P-DET (Polarity Detection) signal<br />

• /G-SEL (Gain Selection) signal<br />

• /PSEL (Reference Pulse Input Multiplication Switch) Signal<br />

• SEN (Absolute Data Request) signal<br />

• /DEC (Origin Return Deceleration Switch) signal<br />

• /MODE 0/1 (Mode Switch Input) signal<br />

• /START-STOP (Program Table Operation Start-Stop Input)<br />

signal<br />

• /JOGP (Forward Jog Input) signal<br />

• /JOGN (Reverse Jog Input) signal<br />

• /HOME (Origin Return Input) signal<br />

• /PGMRES (Program Table Operation Reset Input) signal<br />

• /SEL0 (Program Step Selection Input 0) signal<br />

• /SEL1 (Program Step Selection Input 1) signal<br />

• /SEL2 (Program Step Selection Input 2) signal<br />

• /SEL3 (Program Step Selection Input 3) signal<br />

• /SEL4 (Program Step Selection Input 4) signal<br />

• /JOG0 (Jog Speed Table Selection Input 0) signal<br />

• /JOG1 (Jog Speed Table Selection Input 1) signal<br />

• /JOG2 (Jog Speed Table Selection Input 2) signal<br />

A signal can be allocated and the positive and negative logic<br />

can be changed.<br />

Continued on next page.<br />

I/O Signals<br />

Sequence<br />

Input<br />

Signals<br />

SERVO-<br />

PACKs<br />

Input<br />

Signals<br />

for<br />

Which<br />

Allocations<br />

Can Be<br />

Changed<br />

Σ-7S FT83 Specification<br />

329