Option Modules<br />

Safety Option Module<br />

Specifications<br />

Basic Specifications<br />

Operating<br />

Conditions<br />

Item<br />

Surrounding Air<br />

Temperature<br />

Storage Temperature<br />

Surrounding Air<br />

Humidity<br />

Storage Humidity<br />

0˚C to +55˚C<br />

−20˚C to +85˚C<br />

90% relative humidity<br />

max.<br />

90% relative humidity<br />

max.<br />

Specification<br />

There must be no freezing or condensation.<br />

Vibration Resistance 4.9 m/s 2<br />

Shock Resistance 19.6 m/s 2<br />

Degree of Protection<br />

Pollution Degree<br />

IP10<br />

2<br />

• Must be no corrosive or flammable gases.<br />

• Must be no exposure to water, oil, or chemicals.<br />

• Must be no dust, salts, or iron dust.<br />

Altitude<br />

1000 m max.<br />

Do not use the SERVOPACK in the following locations:<br />

Others<br />

Locations subject to static electricity noise, strong electromagnetic/<br />

magnetic fields, or radioactivity<br />

Compliance with UL Standards, EU Directives, and Other Safety Standards<br />

(in Combination with SERVOPACK)<br />

Item<br />

North American Safety Standards<br />

Machinery Directive<br />

(2006/42/EC)<br />

European<br />

Directives<br />

EMC Directive<br />

(2004/108/EC)<br />

Low Voltage Directive<br />

(2006/95/EC)<br />

UL61800-5-1<br />

CSA C22.2 No.274<br />

EN ISO 13849-1: 2008/AC: 2009<br />

EN 55011/A2 group 1, class A<br />

EN 61000-6-2<br />

EN 61000-6-4<br />

EN 61800-3<br />

EN 50178<br />

EN 61800-5-1<br />

Specification<br />

Safety of Machinery EN ISO 13849-1, IEC 60204-1<br />

Safety<br />

Functional Safety IEC 61508-1 to IEC 61508-4, IEC 62061, and IEC 61800-5-2<br />

Standards<br />

EMC IEC 61326-3-1<br />

IEC 61800-5-2 IEC 60204-1<br />

Safe Torque Off (STO) Stop Category 0<br />

Safe Stop 1 (SS1) Stop Category 1<br />

Safety Function<br />

Safe Stop 2 (SS2) Stop Category 2<br />

Safely Limited Speed<br />

(SLS)<br />

Number of Blocks 2<br />

Input signals: 2 channels (redundant signals),<br />

Safety Function A<br />

output signals: 1 channel<br />

Input signals: 2 channels (redundant signals),<br />

Safety Function B<br />

output signals: 1 channel<br />

Continued on next page.<br />