NEW<br />

PROTECTION DEVICES<br />

miniature circuit breakers (MCBs)<br />

Provides protection & control of circuits against overloads & short-circuits in domestic, commercial &<br />

industrial electrical distribution systems<br />

Available in 1-4 pole, 0.5 to 100A with type B, C or D tripping characteristics<br />

MCB Type NB---A NC---N ML---A ND---A NM---<br />

Range 6-63A 0.5-63A 6-40A 0.5-63 80/100<br />

Poles 1-4 1-4 SP&N 1-4 1-4<br />

Breaking Capacity<br />

IEC 898-1995 10kA 10kA 6kA 10kA –<br />

IEC 947-2 15kA 15kA 7.5kA 15kA 10kA<br />

Rated voltage 230/415V 230/415V 230V 230/415 230/415<br />

<strong>Electrical</strong> endurance<br />

0.5 to 32A 20,000 20,000 10,000 20,000 –<br />

40 to 63A 10,000 10,000 10,000 10,000 –<br />

80 to 100A – – – – 20,000<br />

Touch proof terminals i.e. protection against direct contact<br />

Bi-connect facility i.e cable <strong>and</strong> busbar can be terminated separately allowing safe & fast connection<br />

Conform to the latest version of the international st<strong>and</strong>ards IEC 898-1995 / IEC 947-2 / IS 8828-1996<br />

Low let-through energy (class 3) saves power <strong>and</strong> reduces heat build-up<br />

Two position din rail clips allows fast installation<br />

Windows at the sides of MCB enable auxiliaries <strong>and</strong> earth leakage add-on blocks to be fitted providing<br />

additional protection <strong>and</strong> control<br />

Suitable for DC applications – 1 pole up to 60V, 2 poles in series upto 125V<br />

“NC” MCBs calibrated at 40 o C<br />

MCB auxiliaries & accessories<br />

Auxiliaries snap fit to the side of MCBs <strong>and</strong> providing additional protection or control<br />

Auxiliary contact (1NO + 1NC) – allows remote indication of the device contacts, to which it is associated<br />

Trip Alarm contact – provides indication if the MCB trips due to fault. MCB cannot be switched on without<br />

resetting<br />

Shunt release – allows remote tripping of the device. Available in voltage ratings 230V AC & 9-48V DC<br />

Under-voltage release – allows MCB to trip when the voltage falls by 35% & allows MCB to be closed only<br />

when the Voltage is above 70% of the nominal voltage. AC & DC versions available<br />

Locking kit – allows locking of the device<br />

Flush mounting kits available<br />