PROTECTION DEVICES<br />

residual current circuit breakers (RCCBs)<br />

Opens the circuit automatically in the event of an earth leakage<br />

Available in 2 & 4 pole with sensitivities 30, 100 & 300mA<br />

Available in 25, 40, 63 & 100A<br />

Conforms to IEC 1008<br />

Protection against nuisance tripping i.e. All Hager RCCBs are protected against transient voltages<br />

(lightening, inductive, switching etc.)<br />

Auxiliary contact <strong>and</strong> remote tripping accessory available.<br />

RCBOs<br />

Combines the overload & short-circuit protection of an MCB with the earth leakage protection of an RCCB<br />

Available in current ratings from 6-32A in 2 pole 30mA <strong>and</strong> 300mA sensitivities<br />

Breaking capacity 4.5kA conforming to IEC 1009<br />

Indicator to show whether tripping is due to overcurrent or earth leakage faults<br />

Protection against nuisance tripping<br />

Special RCBOs with fly lead available for mounting on TPN vertical busbar system<br />

RCCB add-on blocks<br />

Designed to be fitted to the right side of 2 & 4 Pole MCBs<br />

The combined unit provides protection against overload, short-circuit <strong>and</strong> earth leakage<br />

Current Rating 32 & 63A for use with NB, NC, ND MCBs<br />

Current Rating 100A for use with NM MCBs<br />

Available in 2 & 4 pole with sensitivities 30mA, 100mA & 300mA upto 63A<br />

Available in 2 & 4 pole with sensitivities 30mA & 300mA for 100A<br />

Breaking capacity of combined unit 10kA conforming to IEC 898/IEC 947-2<br />

Protection against nuisance tripping<br />

earth leakage relays<br />

The relay ensures the monitoring of earth leakage currents<br />

It trips in the event of a break in the relay/core link<br />

Positive reset is required after a fault is detected<br />

It can have either fixed (30mA & 300mA) or adjustable sensitivities (30/100/300mA, 1A, 3A), time delay is<br />

also available for selectivity purposes<br />

Visual display of fault by red LED<br />

Protection against nuisance tripping<br />

Detection torroids which link with relays are available in circular (35mm to 70mm) cross-section<br />

voltage surge devices<br />

These devices protect electronic equipment against transient voltage surges caused by lightening strikes<br />

or switching of motors, transformers etc.<br />

The device functions by creating a link between mains <strong>and</strong> earth during surge peaks <strong>and</strong> the link allows<br />

the current to be channelled safely to the earth<br />

VSDs do not replace the lightening rod but are complimentary<br />

Replacement cartridge available for SP140D / SP 440D<br />

Type of Protection Cat. Ref No. of poles Imax In Up Uc<br />

Main Protection SP140D 1P 40kA 15kA 1.2KV 275V<br />

Protection against Fine Protection in<br />

transient voltage<br />

surges wave 8/20 sec<br />

addition to main SP208 1P&N 8kA 2kA 1.5KV 275V<br />

SP440D TP&N 40kA 15kA 1.2KV 275V<br />

SP175D 1P 75kA – 4KV 255V<br />

Imax – The max. one shot surge current the VSD can withst<strong>and</strong>.<br />

In – The nominal value of current that VSD can withst<strong>and</strong> at least 20 times <strong>and</strong> still be serviceable<br />

Up – The max. voltage that is measured across the terminals of the VSD when ‘In’ is applied.<br />

Uc – The max. voltage which may be continuously applied to the VSD.