10.12.2012 Views

AIR CIRCUIT BREAKERS - Electrical and Electronics Division

AIR CIRCUIT BREAKERS - Electrical and Electronics Division

AIR CIRCUIT BREAKERS - Electrical and Electronics Division

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NEW<br />

AUTOMATION & CONTROL DEVICES<br />

isolating switches<br />

For use as a switch disconnector in all types of circuit<br />

AC 22A utilization category<br />

Available in 2, 3 & 4 pole versions with ratings from 25A to 100A<br />

2 pole 25A & 32A also available in pilot light version<br />

All switches have a green/red mechanical indication giving a positive contact indication<br />

Suitable for DC application 48V – 1 pole <strong>and</strong> 110V – 2 pole in series<br />

2-way/centre-off changeover switches<br />

These devices allow changeover from one source of supply to another with centre-off position<br />

AC 21A utilization category<br />

Available in 2 pole 25 & 40A <strong>and</strong> 4 pole 40A versions<br />

Suitable for use on 110V DC<br />

modular electromechanical/digital time switches<br />

1 & 2 channel quartz time switches for hourly daily <strong>and</strong> weekly programming<br />

These can be used to control lighting, heating, ventilation, household appliances etc.<br />

Minimum swtiching time – 30 min. for daily dial <strong>and</strong> 3 hrs. for weekly dial<br />

All time switches are rated for 16A 240V AC1 <strong>and</strong> have supply failure reserve upto 150 hrs.<br />

Digital time switches are in 1 & 2 channel daily, 1 channel weekly, 5-20 pre-recorded adjustable<br />

programmes<br />

Operating reserve 3 years<br />

Pulsed output possible<br />

time lag switches<br />

The device controls lighting circuits with automatic switch-off after a pre-set time<br />

Time delay is adjustable from 24sec. to 12 min.<br />

It is equipped with a 2 position dial – permanent/timed lighting implementation facility<br />

Rated for 16A 240V AC1 <strong>and</strong> is suitble for use with pushbuttons only<br />

EM003 time lag switch available with addition function, when push button is pressed for more than three<br />

secs the lights switch on for one hour. This is useful for maintenance personnel<br />

Pre-warning device EM002 dims lights to 50% for 24 secs before final switch off<br />