02.02.2018 Views

2018 Adhesives and Sealants Equipment Guide

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Adhesive & <strong>Sealants</strong> <strong>Equipment</strong> <strong>Guide</strong><br />

Melters | 1-89<br />

VersaBlue ® XN <strong>and</strong> XC Series<br />

Adhesive Melters<br />

Options<br />

Return Hose<br />

Flow<br />

Control<br />

Internal<br />

Pressure<br />

Indication<br />

External<br />

Pressure<br />

Inputs<br />

Digital Pressure<br />

Input<br />

Auxiliary<br />

Hose/Appl<br />

Pairs<br />

Auxiliary<br />

Motor Control<br />

Auxiliary<br />

Motor Control<br />

Type<br />

Voltage<br />

I/O &<br />

Indication<br />

Reserved<br />

Control<br />

system<br />

Air Run-up<br />

Applicator<br />

solenoid<br />

Control<br />

Sensor type<br />

Heat Exchanger/<br />

ACM<br />

1 X A X X A X X 4 D A A X G P X<br />

Boxe<br />

25<br />

Box<br />

26<br />

Box<br />

27<br />

Box<br />

28<br />

Box<br />

29<br />

Box<br />

30<br />

Box<br />

31<br />

Box<br />

32<br />

Box<br />

33<br />

Box<br />

34<br />

Box<br />

35<br />

Box<br />

36<br />

Box<br />

37<br />

Box<br />

38<br />

Box<br />

39<br />

Box<br />

40<br />

Options<br />

Box<br />

25<br />

Return Hose (1)<br />

Description<br />

Code<br />

Tank 1 1<br />

Tank 2 2<br />

Tanks 1 & 2 3<br />

None<br />

(1)<br />

Includes 1 hose fitting <strong>and</strong> MPCV per return manifold. Requires<br />

heating zone per manifold.<br />

Box<br />

26<br />

Flow Control<br />

Description<br />

Auto flow cont. w/ min speed<br />

Auto flow cont.<br />

(1)<br />

Requires IPI in box 21.<br />

Box<br />

27<br />

X<br />

Code<br />

(1) Pressure Build-up N<br />

SV w/ Indication (no MPCV)<br />

None (St<strong>and</strong>ard MPCV)<br />

Internal Pressure Indication (1)<br />

Description<br />

Post-filter pressure Indication<br />

Pre-filter pressure Indication<br />

Pre & Post filter pressureIndication<br />

None<br />

T<br />

B<br />

O<br />

X<br />

Code<br />

(1)<br />

Output pressure control is st<strong>and</strong>ard functionality when pressure<br />

indication is selected.<br />

Box<br />

28<br />

External Pressure Inputs<br />

Description<br />

A<br />

G<br />

H<br />

X<br />

Code<br />

4 inputs F<br />

8 inputs E<br />

(1) 12 inputs T<br />

(1) 16 inputs S<br />

None<br />

(1)<br />

Available only with twin tank <strong>and</strong> 200L configurations.<br />

Box<br />

29<br />

Digital Pressure Input<br />

Description<br />

X<br />

Code<br />

4 Inputs F<br />

8 Inputs E<br />

12 Inputs T<br />

None<br />

X<br />

Box<br />

30<br />

Box<br />

31<br />

Box<br />

32<br />

Auxiliary H/G Pairs (@ Elec. Panel)<br />

Description<br />

Code<br />

2 H/G (Included in Base Unit) A<br />

6 H/G B<br />

10 H/G C<br />

Auxiliary Motor Control (Qty)<br />

Description<br />

Code<br />

Max. 6 #<br />

None<br />

Auxiliary Motor Control Type<br />

Description<br />

X<br />

Code<br />

(1) AC PowerFlex 40 (750W) A<br />

(1) Servo Ultra 3000 S<br />

(2) 1x AC Lenze Vector 8200 L<br />

None (St<strong>and</strong>ard)<br />

(1)<br />

Rockwell PLC only.<br />

(2)<br />

Only with S7 control system (A in box 36).<br />

Box<br />

33<br />

Box<br />

34<br />

Box<br />

35<br />

Voltage<br />

Description<br />

200-240 3P ∆ (Red Main Switch,<br />

3-Pole)<br />

200-240 3P ∆ (Black Main Switch,<br />

3-Pole)<br />

380-415 Y (Red Main Switch<br />

4-Pole)<br />

380-415 Y (Black Main Switch,<br />

4-Pole)<br />

I/O & Indication<br />

Description<br />

St<strong>and</strong>ard -XS2 (Discrete)<br />

Warning Light Tower<br />

WLT <strong>and</strong> Discrete I/O<br />

None<br />

Reserved<br />

Reserved<br />

Description<br />

X<br />

Code<br />

2<br />

B<br />

4<br />

C<br />

Code<br />

D<br />

W<br />

K<br />

X<br />

Code<br />

X<br />

Box<br />

36<br />

Control System<br />

Description<br />

Siemens S7-300 w/ TP270<br />

ControlLogix ENet ext. PView1000<br />

ControlLogix CNet ext. PView1000<br />

Code<br />

A<br />

F<br />

T<br />

Box<br />

37<br />

Air Run-up (1)<br />

Description<br />

Code<br />

4 outputs 4<br />

8 outputs 8<br />

12 outputs 12<br />

16 outputs 16<br />

None<br />

X<br />

(1)<br />

Air run-up kit sold separately<br />

Box<br />

38<br />

Box<br />

39<br />

Box<br />

40<br />

Applicator Solenoid Control<br />

Description<br />

Std VersaBlue<br />

Pat. Cont. through GS conn.<br />

None<br />

PT100<br />

Ni-120<br />

Sensor Type<br />

Description<br />

Heat Exchanger/ACM<br />

Description<br />

Heat Exchanger<br />

ACM Connectivity<br />

Heat Exchanger <strong>and</strong> ACM<br />

None<br />

Code<br />

G<br />

P<br />

X<br />

Code<br />

P<br />

N<br />

Code<br />

E<br />

A<br />

B<br />

X<br />

To place your order, NAD call 1-888-NORDSON (1-888-667-3766), fax 1-770-497-3733 or online at www.enordson.com.<br />

International Orders, call 1-440-985-4797, fax 1-440-985-1096, or email intcustomerservice@nordson.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!