13-10 | Controls<br />

Concert Series Controllers<br />

Specifications — Basic Flow Controller<br />

Parameter<br />

Number of flow channels Supports up to 2<br />

Control modes<br />

Pressure transducer inputs Supports up to 2<br />

Pressure transducer options<br />

Line speed reference inputs 1<br />

Line speed reference outputs<br />

Operating temperature range<br />

Ambiet temperature range<br />

Temperature control stability<br />

Temperature control sensor options<br />

Maximum heating capacity<br />

Channel 1,2 (each)<br />

Channel 3<br />

Electrical requirements<br />

Input/Output capability<br />

Weight (approx.)<br />

Ingress protection<br />

Specification<br />

Manual, Pressure, Gear to Line, Flow w/Pressure Build<br />

0-10 VDC, 4-20 mA<br />

0-10 VDC, 4-20 mA<br />

40 to 204 ºC (100 to 400 ºF)<br />

0 to 50 ºC (32 to 122 ºF)<br />

±1 ºC (2 ºF)<br />

Nickel 120 Ohm RTD, Platinum 100 Ohm RTD<br />

1,200 watts per channel/1,000 watts per zone<br />

2,800 watts per channel/1,800 or 1,000 watts per zone<br />

200/240 VAC 50/60 Hz, single-phase<br />

240 VAC 50/60 Hz, 3-phase<br />

4 inputs/3 outputs<br />

30 lb<br />

IP33<br />

Specifications — Basic Temperature Controller<br />

Parameter<br />

Specification<br />

Number of channels 3<br />

Operating temperature range<br />

40 to 204 ºC (100 to 400 ºF)<br />

Ambiet temperature range<br />

0 to 50 ºC (32 to 122 ºF)<br />

Temperature control stability<br />

±1 ºC (2 ºF)<br />

Temperature control sensor options Nickel 120 Ohm RTD, Platinum 100 Ohm RTD<br />

Maximum heating capacity<br />

Channel 1,2 (each)<br />

Channel 3<br />

Electrical requirements<br />

Input/Output<br />

Weight (approx.)<br />

Ingress protection<br />

1,200 watts per channel/1,000 watts per zone<br />

2,800 watts per channel/1,800 or 1,000 watts per zone<br />

200/240 VAC 50/60 Hz, single-phase<br />

240 VAC 50/60 Hz, 3-phase<br />

4 inputs/3 outputs<br />

30 lb<br />

IP33<br />

To place your order, NAD call 1-888-NORDSON (1-888-667-3766), fax 1-770-497-3733 or online at www.enordson.com.<br />

International Orders, call 1-440-985-4797, fax 1-440-985-1096, or email intcustomerservice@nordson.com

Hooray! Your file is uploaded and ready to be published.