13-36 | Controls<br />

Applicator Driver Selection Chart<br />

LogiComm OEM<br />

Applicator Driver Board<br />

LogiComm<br />

Applicator Driver<br />

e driver<br />

Features:<br />

Applicators<br />

e.dot+, e.dot, E-400, All hot melt <strong>and</strong> liquid e.dot<br />

LA 820, WM 801 adhesive electric applicators<br />

Outputs 4 4 or 8 1<br />

Coils Per Channel 1–2 in series Varies per applicator 1–3 in series<br />

Input Triggers 4 4 1<br />

Normal Mode Yes Yes Yes<br />

Dot Mode Yes Yes Yes<br />

Dot Time 0.05–4.95 ms 0.05–12.70 ms 0.05–4.95 ms<br />

Purge Yes Yes Yes<br />

Flush Yes Yes Yes<br />

Hammering Yes Yes Yes<br />

Programming:<br />

Spike Amplitude<br />

Software LCD / Keypad Software<br />

Spike Duration Software LCD / Keypad Software<br />

Hold Duration Software LCD / Keypad Software<br />

# Coils Wire in series LCD / Keypad Wire in series<br />

User Interface:<br />

Interface<br />

Diagonistic LEDs — power Backlit LCD graphic with LEDs: power, trigger, output, 3<br />

(230V <strong>and</strong> 24V), enable, fault keypad <strong>and</strong> on/off switch. 4 thermal LEDs (fault warning or<br />

(short/open circuit) LEDs for triggers, 4 to 8 LEDs OK), open, short, dot, for each<br />

Diagnostic LEDs per channel— for outputs, LED for power, LED channel; purge button (press in);<br />

trigger, output, fault, dot mode/ for fault, <strong>and</strong> LED for alarm. two knobs for adjusting dot time.<br />

purge<br />

Purge button <strong>and</strong> buttons to<br />

scroll through LCD<br />

Connections Terminal Block Terminal block or Connector Terminal Block<br />

Other:<br />

Special Features<br />

Modbus TCP communication<br />

Ready output — potential free<br />

contact rated at 0.25 A @<br />

24 VDC, closes on unit ready<br />

Presets for all legacy<br />

applicators, current mode <strong>and</strong><br />

HD mode<br />

Port for software to set applicator<br />

settings<br />

Software Upgrades Software utility USB 2.0 <strong>and</strong> 1.1 via NCM None<br />

Major Replacement<br />

Parts<br />

Full set of service kits Full set of service kits None<br />