Malaysia Water Research Journal<br />

3.3 Result of Dam Simulation Testing<br />

From the testing, it was found that certain setting of Inverter Pump will<br />

cause to decrease its water level and subsequently interrupting the ram pump<br />

performance. However, at certain setting from 36 to 37Hertz, the ram pump<br />

operated intermittently for sometimes. These could be as an early warning sign<br />

of ram pump system failure and it show that the ram pump requires a certain<br />

amount of detention water above the ram pump to give constant water pressure<br />

to the ram pump. Results of dam simulation testing are shown in Table 5. This<br />

testing scenario had proved that ram pump requires a small size of retention<br />

water structure or mini dam, with a minimum capacity of 2,271 liter for continuous<br />

ram pump operation.<br />

Inverter Pump Setting<br />

Flowrate (Hertz)<br />

Table 5. Summary Result of Dam Simulation Testing.<br />

Ram Pump Operation<br />

Status<br />

Flowrate<br />

(m3/hr)<br />

33.0 Not Operating No Data<br />

33.5 Not Operating No Data<br />

34.0 Not Operating No Data<br />

34.5 Not Operating No Data<br />

35.0 Not Operating No Data<br />

35.5 Not Operating No Data<br />

36.0 Intermittent Operation 151.16<br />

36.5 Intermittent Operation 151.16<br />

37.0 Intermittent Operation 161.7<br />

37.8 In Operation 151.9<br />

38.0 In Operation 137.8<br />

39.0 In Operation 137.0<br />

3.4 Result of Pre-River Simulation Testing<br />

Generally, form this testing scenario; it is possible for a ram pump to operate<br />

without the assistance of retention water. However, it requires some complicated<br />

valves controlling procedures. Pressure gauge at ram pump does not give high<br />

reading, meaning that no additional pressure at ram pump during high and low<br />

peak of flows. However, by the assistance of two valve’s setting, Valves C and<br />

Valves D, had given the possibility for the ram pump to continuously operate.<br />

46<br />

Institut Penyelidikan Hidraulik Kebangsaan Malaysia (NAHRIM)<br />

National Hydraulic Institute of Malaysia (NAHRIM)