10.07.2018 Views

mag

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Malaysia Water Research Journal<br />

Figure 3. Water Flows and Valves Setting During the Ram Pump Testing.<br />

3.5 Result of River Simulation Testing<br />

As the result of Pre-River Simulation Testing, some flow rate setting on Inverter<br />

Pump were found as stable testing methodologies. In this test, Inverter Pump had<br />

been set to six (6) setting which generate incoming water to ram pump from 34.4<br />

to 40m3/hr(50 Hertz). The summary of testing result is as shown in Table 6.<br />

No.<br />

Table 6. Summary of River Simulation Testing<br />

Inverter<br />

Pump Setting<br />

Flowrate<br />

(m3/hr)<br />

Average<br />

Incoming<br />

Water Supply<br />

to Ram Pump<br />

Flowrate (liter/<br />

second)<br />

Average<br />

Delivery Water<br />

Supply from<br />

Ram Pump<br />

Flowrate (liter/<br />

second)<br />

Percentage<br />

Differences<br />

between<br />

Incoming and<br />

Delivery<br />

1 34.4 2.022 0.079 3.89%<br />

2 36.0 2.007 0.144 7.17%<br />

3 37.6 1.933 0.103 5.30%<br />

4 38.4 1.880 0.065 3.47%<br />

5 39.2 1.852 0.072 3.87%<br />

6 40.0 1.784 0.096 5.40%<br />

Institut Penyelidikan Hidraulik Kebangsaan Malaysia (NAHRIM)<br />