10.07.2018 Views

mag

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Malaysia Water Research Journal<br />

No. of ram pump required based on<br />

early finding.<br />

[Early finding: 5hours at 7.5liter/second<br />

supplying 145m3 for a unit of ram<br />

pump at 1.5Bar or 30psi]<br />

Option 1: Three (3) unit of ram pump<br />

at 1.5 Bar or 30psi<br />

Option 2: One (1) unit ram pump with<br />

achievement at 3.0Bar or 60psi<br />

3.6 Result of Free Flow Simulation Testing<br />

In this testing, the testing ranges of the Inverter Pump are from 36 Hertz to<br />

maximum 50 Hertz. From the testing, due to the distance from Inverter Pump<br />

to flow meter (before Ram Pump), the amount of the losses is about 27 - 34%.<br />

However, there are only small reading differences between flow meter reading<br />

and Inverter Pump manufacturer calculation. As such, this free flow testing result<br />

was used as references for acceptable tolerance between Inverter Pump Setting<br />

and real flow meter measurement. The summaries of free flow testing result are<br />

as shown in Table 8.<br />

Setting of<br />

Inverter<br />

Pump<br />

(Hertz)<br />

Table 8. Summary of Free Flow Simulation Testing.<br />

Volume<br />

(liter)<br />

Test Period<br />

(second)<br />

Flowrate<br />

R e c o r d e d<br />

(liter/second)<br />

Flowrate<br />

Calculated<br />

(liter/second)<br />

Percentage<br />

Differences<br />

36 1703 300 5.7 8.0 29%<br />

37 1756 300 5.9 8.2 28%<br />

38 1819 300 6.1 8.4 27%<br />

39 1843 300 6.1 8.7 30%<br />

40 1858 300 6.2 8.9 30%<br />

41 1900 300 6.3 9.1 31%<br />

42 2027 300 6.8 9.3 27%<br />

43 1966 300 6.6 9.5 31%<br />

44 1956 300 6.5 9.8 34%<br />

45 2009 300 6.7 10.0 33%<br />

46 2032 300 6.8 10.2 33%<br />

47 2099 300 7.0 10.4 33%<br />

48 2115 300 7.1 10.7 34%<br />

49 2199 300 7.3 10.9 33%<br />

50 2201 300 7.3 11.1 34%<br />

Institut Penyelidikan Hidraulik Kebangsaan Malaysia (NAHRIM)<br />

49<br />

National Hydraulic Institute of Malaysia (NAHRIM)