Malaysia Water Research Journal<br />

At the setting from 36m3/hr till 38.4m3/hr of Inverter Pump setting, the average<br />

of incoming water supply to and from ram pump and from become deteriorated.<br />

From the Table 6, at the highest setting, 40 m3/hr and at the lowest setting, 34.4<br />

m3/hr of Inverter Pump, the ram pump delivery also become deteriorated. This<br />

leads to the conclusion that optimum water flow rate to the ram pump would<br />

be a requirement. However, due to the river flows fluctuation, the ram pump is<br />

recommended to have water retention structure in order to ensure continuous<br />

performance.<br />

3.6 Result of 24 Hours Simulation Testing<br />

The ram pump could operate for more than 6 hours, 12 hours and 24 hours<br />

continuously. It also found that no breakdown occurs after 24 hours. No heat<br />

development that could lead to component ware and tare. Ram pump had<br />

successfully supplied 11.647 (~12m3) per day or 7.03% of incoming water.<br />

Conversion of the supplied water is: 12m3/day or 0.5m3/hours or 0.0083m3/<br />

minutes or 0.0001388m3/second or 0.1388liter/second (~0.14liter/second). As<br />

recorded by the pressure vessel of ram pump that the pressure decrease by<br />

20% at the end of the testing from 10psi to 8psi, and the ram pump still could<br />

operate. In this test, 165 m3 (1.91 liter/second) had been supplied to ram pump<br />

delivering 0.14 liter/second. From these findings, it can be stated that flow rate<br />

ratio for at site (laboratory or river) and ram pump are 1.91:0.14 liter/second<br />

resulting in the ram pump deliverables at 7% water from the site. This means that,<br />

if the ram pump located near to the river of 1.91 liter/s, the ram pump require 4.5<br />

hours to fill in 2,270 liter seized of water tank. From these findings, the numbers of<br />

selected sized ram pump could be determined by calculation. Tables 7 are the<br />

calculation for determining numbers of ram pump for certain residential usage.<br />

Table 7. Ram Pump Calculation Determining Numbers of Ram Pump for<br />

Certain Residential Usage<br />

Conditions/ Formula/ Input<br />

Resident Population/ Water Demands<br />

or Water Supplied<br />

Water should be received by ram<br />

pump according to ratio formulation<br />

(1:10).<br />

Adjustment of Water Supply In Time of<br />

12 hours or 720 minutes or 43,200seconds<br />

(Proposed 7.00PM to 7.00AM)<br />

Output<br />

1000m3 for 100 people<br />

10,000m3<br />

The River/ Dam Flow Rate Requirement:<br />

= 1000 m3/ 12 hours or 720 minutes or<br />

43,200seconds = 83m3/hour or 1.39<br />

m3/minutes or 0.023 m3/s or 23 liter/<br />

second.<br />

48<br />

Institut Penyelidikan Hidraulik Kebangsaan Malaysia (NAHRIM)<br />

National Hydraulic Institute of Malaysia (NAHRIM)