Malaysia Water Research Journal<br />
At the setting from 36m3/hr till 38.4m3/hr of Inverter Pump setting, the average<br />
of incoming water supply to and from ram pump and from become deteriorated.<br />
From the Table 6, at the highest setting, 40 m3/hr and at the lowest setting, 34.4<br />
m3/hr of Inverter Pump, the ram pump delivery also become deteriorated. This<br />
leads to the conclusion that optimum water flow rate to the ram pump would<br />
be a requirement. However, due to the river flows fluctuation, the ram pump is<br />
recommended to have water retention structure in order to ensure continuous<br />
performance.<br />
3.6 Result of 24 Hours Simulation Testing<br />
The ram pump could operate for more than 6 hours, 12 hours and 24 hours<br />
continuously. It also found that no breakdown occurs after 24 hours. No heat<br />
development that could lead to component ware and tare. Ram pump had<br />
successfully supplied 11.647 (~12m3) per day or 7.03% of incoming water.<br />
Conversion of the supplied water is: 12m3/day or 0.5m3/hours or 0.0083m3/<br />
minutes or 0.0001388m3/second or 0.1388liter/second (~0.14liter/second). As<br />
recorded by the pressure vessel of ram pump that the pressure decrease by<br />
20% at the end of the testing from 10psi to 8psi, and the ram pump still could<br />
operate. In this test, 165 m3 (1.91 liter/second) had been supplied to ram pump<br />
delivering 0.14 liter/second. From these findings, it can be stated that flow rate<br />
ratio for at site (laboratory or river) and ram pump are 1.91:0.14 liter/second<br />
resulting in the ram pump deliverables at 7% water from the site. This means that,<br />
if the ram pump located near to the river of 1.91 liter/s, the ram pump require 4.5<br />
hours to fill in 2,270 liter seized of water tank. From these findings, the numbers of<br />
selected sized ram pump could be determined by calculation. Tables 7 are the<br />
calculation for determining numbers of ram pump for certain residential usage.<br />
Table 7. Ram Pump Calculation Determining Numbers of Ram Pump for<br />
Certain Residential Usage<br />
Conditions/ Formula/ Input<br />
Resident Population/ Water Demands<br />
or Water Supplied<br />
Water should be received by ram<br />
pump according to ratio formulation<br />
(1:10).<br />
Adjustment of Water Supply In Time of<br />
12 hours or 720 minutes or 43,200seconds<br />
(Proposed 7.00PM to 7.00AM)<br />
Output<br />
1000m3 for 100 people<br />
10,000m3<br />
The River/ Dam Flow Rate Requirement:<br />
= 1000 m3/ 12 hours or 720 minutes or<br />
43,200seconds = 83m3/hour or 1.39<br />
m3/minutes or 0.023 m3/s or 23 liter/<br />
second.<br />