2.1.5 Physical properties <strong>and</strong> odour percepti<strong>on</strong><br />

How an odour is perceived <strong>and</strong> its subsequent effects are not straightforward. The<br />

human percepti<strong>on</strong> <strong>of</strong> odour is governed by complex relati<strong>on</strong>ships <strong>and</strong> its properties<br />

need to be c<strong>on</strong>sidered when assessing potential odour effects.<br />

The percepti<strong>on</strong> <strong>of</strong> <strong>the</strong> intensity <strong>of</strong> odour in relati<strong>on</strong> to <strong>the</strong> odour c<strong>on</strong>centrati<strong>on</strong> is not a<br />

linear but a logarithmic relati<strong>on</strong>ship. This means that if <strong>the</strong> c<strong>on</strong>centrati<strong>on</strong> <strong>of</strong> an odour<br />

increases tenfold, <strong>the</strong> perceived increase in intensity will be by a much smaller amount.<br />

Interacti<strong>on</strong>s between mixtures <strong>of</strong> odorous compounds can also occur. These are known<br />

as synergistic effects. An example <strong>of</strong> a synergistic effect is where <strong>on</strong>e odorous<br />

compound disguises or masks <strong>the</strong> presence <strong>of</strong> o<strong>the</strong>r compounds. As <strong>the</strong> odour<br />

c<strong>on</strong>centrati<strong>on</strong> reduces through diluti<strong>on</strong> <strong>the</strong> nature <strong>of</strong> <strong>the</strong> odour may change as different<br />

compounds dominate <strong>the</strong> effect. For example, certain emissi<strong>on</strong>s treated with incorrect<br />

levels <strong>of</strong> odour counteracting agents has been observed to have distinctly different<br />

odour characteristics at source than when diluted downwind. The odour intensity<br />

experienced by an observer is, in general, not equivalent to <strong>the</strong> sum <strong>of</strong> <strong>the</strong> intensities <strong>of</strong><br />

<strong>the</strong> comp<strong>on</strong>ent odorous compounds. The perceived intensity may be greater or less<br />

than <strong>the</strong> comp<strong>on</strong>ents depending <strong>on</strong> <strong>the</strong> synergistic effects <strong>of</strong> <strong>the</strong> compounds present.<br />

Exposure to an odour can result in people becoming desensitised so that <strong>the</strong>y can no<br />

l<strong>on</strong>ger detect <strong>the</strong> odour even though <strong>the</strong> odorous chemical is c<strong>on</strong>stantly present in <strong>the</strong><br />

air. This is sometimes known as olfactory fatigue. For example, people working in an<br />

envir<strong>on</strong>ment with a persistent odour are <strong>of</strong>ten unaware <strong>of</strong> its presence <strong>and</strong> may not be<br />

aware if <strong>the</strong> odour is having an impact <strong>on</strong> <strong>the</strong> surrounding community.<br />

2.1.6 Factors that influence magnitude <strong>of</strong> an odour problem<br />

Factors that influence <strong>the</strong> c<strong>on</strong>trol <strong>of</strong> odour <strong>from</strong> commercial kitchens include:<br />

Size <strong>of</strong> <strong>the</strong> cooking facility: This influences <strong>the</strong> intensity <strong>of</strong> <strong>the</strong> odour <strong>and</strong><br />

volume <strong>of</strong> ventilati<strong>on</strong> air to be h<strong>and</strong>led.<br />

Type <strong>of</strong> food prepared: This affects <strong>the</strong> chemical c<strong>on</strong>stituents within <strong>the</strong><br />

ventilati<strong>on</strong> air.<br />

Type <strong>of</strong> cooking appliances used: This dictates <strong>the</strong> level <strong>of</strong> fat, water droplets <strong>and</strong><br />

temperature within <strong>the</strong> ventilati<strong>on</strong> air.<br />

2.1.7 Characteristics <strong>of</strong> different food types <strong>and</strong> cooking appliances<br />

The odour <strong>and</strong> grease characteristics <strong>from</strong> a range <strong>of</strong> commercial kitchen types are<br />

summarised in Table 2.2 (CIEH 1996 [4] ).<br />

The grease <strong>and</strong> moisture characteristics anticipated <strong>from</strong> a range <strong>of</strong> kitchen appliances<br />

are provided in Table 2.3 (LPS, 2003 [5] ).<br />