4.10.3 Cost <strong>of</strong> noise abatement equipment<br />

Table 4.15 identifies <strong>the</strong> cost <strong>of</strong> noise abatement equipment at varying air volumes.<br />

Table 4.15 Anticipated cost <strong>of</strong> abatement treating noise emissi<strong>on</strong>s <strong>from</strong> kitchen<br />

ventilati<strong>on</strong> systems<br />

Air<br />

Volume<br />

Fan<br />

Housing<br />

Acoustic<br />

Lagging<br />

(Circular<br />

Ductwork)<br />

Acoustic<br />

Lagging<br />

(Rectangular<br />

Ductwork)<br />

74<br />

Attenuati<strong>on</strong><br />

(Circular<br />

Ductwork)<br />

Attenuati<strong>on</strong><br />

(Rectangular<br />

Ductwork)<br />

1.0m³/s £1,700 £110 £130 £200 £250<br />

3.0m³/s £1,900 £180 £210 £700 £400<br />

5.0m³/s £2,200 £210 £250 £1,050 £550<br />

Note: All <strong>the</strong> above costs are based <strong>on</strong> a fan running at a noise rating <strong>of</strong> NR60 with an<br />

anticipated maintained space noise rating <strong>of</strong> NR40.<br />

4.10.4 Relative cost effectiveness <strong>of</strong> odour abatement systems<br />

Table 4.16 compares <strong>the</strong> anticipated level <strong>of</strong> noise c<strong>on</strong>trol against <strong>the</strong> estimated cost<br />

for installing <strong>and</strong> maintaining a system.<br />

Table 4.16. Relative cost effectiveness <strong>of</strong> odour abatement systems<br />

<strong>Noise</strong><br />

Abatement<br />

Type<br />

Level <strong>of</strong> <strong>Noise</strong><br />

Abatement<br />

Capital<br />

Cost<br />

M<strong>on</strong>thly<br />

Maintenance &<br />

Running<br />

Fan Housing Medium High Low Low<br />

Acoustic<br />

Lagging<br />

(Circular<br />

Ductwork)<br />

Acoustic<br />

Lagging<br />

(Rectangular<br />

Ductwork)<br />

Attenuati<strong>on</strong><br />

(Circular<br />

Ductwork)<br />

Attenuati<strong>on</strong><br />

(Rectangular<br />

Ductwork)<br />

Low Low Low Low<br />

Medium Low Low Low<br />

Annual<br />

Maintenance &<br />

Running<br />

Medium Medium Medium Medium<br />

Medium Medium Medium Medium<br />

Note: The above table uses <strong>the</strong> costs associated with an average air volume <strong>of</strong> 3.0 m³/s.