upgraded to minimise <strong>the</strong> impact <strong>of</strong> an existing premises (to prevent statutory<br />
nuisance). The factors that dictate <strong>the</strong> level <strong>of</strong> expenditure that an operator can be<br />
expected to pay will depend <strong>on</strong> a number <strong>of</strong> factors:<br />
• Size <strong>of</strong> <strong>the</strong> cooking facility;<br />
• Type <strong>of</strong> food prepared;<br />
• Type <strong>of</strong> cooking appliances used; <strong>and</strong><br />
• Compliance with <strong>the</strong> requirements <strong>of</strong> Best Practicable Means.<br />
For <strong>the</strong> purpose <strong>of</strong> this report, interpreting Best Practicable Means must take into<br />
account <strong>the</strong> following:<br />
• Local c<strong>on</strong>diti<strong>on</strong>s <strong>and</strong> circumstances will vary <strong>from</strong> case to case <strong>and</strong> will<br />
depend <strong>on</strong> <strong>the</strong> proximity <strong>of</strong> residential properties <strong>and</strong> local planning restricti<strong>on</strong>s.<br />
• The current state <strong>of</strong> technical knowledge for c<strong>on</strong>trolling odour is described<br />
in secti<strong>on</strong> 4.7 <strong>of</strong> this report. It is recognised that developments are c<strong>on</strong>tinuously<br />
being made in <strong>the</strong> field <strong>of</strong> emissi<strong>on</strong>s c<strong>on</strong>trol, so due regard must be given to<br />
any new techniques/technologies that can be designed to suit <strong>the</strong> commercial<br />
kitchen situati<strong>on</strong>.<br />
• The financial implicati<strong>on</strong>s <strong>of</strong> odour c<strong>on</strong>trol must be weighed against <strong>the</strong> harm<br />
caused by emissi<strong>on</strong> <strong>of</strong> <strong>of</strong>fensive odour to local residents.<br />
• Operati<strong>on</strong> <strong>of</strong> <strong>the</strong> site for example, <strong>the</strong> design, installati<strong>on</strong>, maintenance <strong>and</strong><br />
manner, periods <strong>of</strong> operati<strong>on</strong> <strong>of</strong> plant <strong>and</strong> machinery, <strong>and</strong> <strong>the</strong> design,<br />
c<strong>on</strong>structi<strong>on</strong> <strong>and</strong> maintenance <strong>of</strong> buildings <strong>and</strong> structures etc.<br />
In this secti<strong>on</strong> <strong>the</strong> typical costs <strong>of</strong> two ventilati<strong>on</strong> systems are presented based <strong>on</strong>:<br />
• a general kitchen operati<strong>on</strong> situati<strong>on</strong> (Table 4.12); <strong>and</strong><br />
• a high or very high grease/smoke situati<strong>on</strong> (Table 4.13). This system involves a<br />
sec<strong>on</strong>d pass through an ESP.<br />
The costing provide an indicati<strong>on</strong> <strong>of</strong>:<br />
• capital cost (not including installati<strong>on</strong>);<br />
• m<strong>on</strong>thly maintenance <strong>and</strong> running costs; <strong>and</strong><br />
• annual maintenance <strong>and</strong> running costs.<br />
The costings presented in Table 4.12 <strong>and</strong> 4.13 are based <strong>on</strong> typical costs 2004 <strong>and</strong><br />
c<strong>on</strong>sider <strong>the</strong> following scenarios:<br />
• general situati<strong>on</strong> treated using pre filter panel followed by bag filter (i.e. <strong>on</strong>ly<br />
grease c<strong>on</strong>trol);<br />
• general situati<strong>on</strong> treated using pre filter panel followed by bag <strong>and</strong> HEPA filter<br />
(i.e. <strong>on</strong>ly grease c<strong>on</strong>trol);<br />
• general situati<strong>on</strong> treated using pre <strong>and</strong> fine filters followed by activated carb<strong>on</strong>;<br />
68