<strong>Getting</strong> <strong>Started</strong><br />
component has been positioned you can place the reference name where you want,<br />
recommended is centrally above the symbol.<br />
94<br />
Now activate the option 'Automatically' in the group 'Placing' within<br />
the Control cabinet manager. Double click in the list on<br />
MPCBs, '-F2' and '-F3' and the components are positioned<br />
automatically in the Control cabinet layout. Again, position the<br />
reference name centrally above the components. Position the in the<br />
'automatic circuit breaker 2pole' '-F4' in the same way.<br />
Next, place a symbol on the second top hat rail. Turn the automatic<br />
positioning off again. Double click on the entry 'CPU 315-2 DP_MC'<br />
and place it at 787,5/600,0 mm. Set the input ('SM 321 1BH00<br />
16x24V DC') and output ('SM 322 1BH00 16x24V DC') unit as you<br />
did earlier with the MCBs, using 'Automatically' placing and a 'double<br />
click'.<br />
Turn 'Automatically' off again and repeat the process for the contactors. Begin with the<br />
contactor '-K1' 'DILER-40-G', the co-ordinates are 787,5/450,0 mm. Turn<br />
'Automatically' on an position the coils '-Q4'; '-Q5' and '-Q6' ('DIL00M-G/22') again<br />
with a 'double click'.<br />
Next , place the transformer. Turn 'Automatically' off again. This time there is no<br />
corresponding symbol for the transformer in the database, so a rectangle is drawn, based<br />
on the dimensions given in the database. Position this at 1200,0/762,5 mm.<br />
Inserting terminals<br />
There are various ways of inserting terminals into the layout diagram, either one by one<br />
or as a complete strip. In this example we will place a complete terminal strip.<br />
Place the first terminal '-X0, Terminal Insta. 2,5mm' without 'Automatically' placing<br />
and position it to the co-ordinates 787,5/337,5 mm. To place further terminals, select<br />
the same terminal again in the Control cabinet manager.