Design capture<br />
Assign the 'NO_Contactor' to the 'Emergency Off' coil. After the contact has been assigned, the<br />
cross-reference is applied online to the contact and the contact comb after clicking the left mouse<br />
button anywhere in the drawing field. Exit the Symbol Explorer with 'Cancel'.<br />
Hint<br />
This procedure can also be reversed. This means that a contact can<br />
be loaded first and a part number (from the database) can be<br />
assigned. As the part is assigned, the automatic process identifies<br />
and manages the contact arrangement even when the coil is not yet<br />
positioned on the drawing sheet.<br />
Cross-reference Navigator<br />
Now you can learn how to access the position a cross-reference is pointed to, quickly<br />
and easily.<br />
Let's use the contact comb of the contactor 'Feed forward' as an example. Note the<br />
cross-reference text at the left of the comb; this represents the position of the associated<br />
contact.<br />