Design capture<br />

Assign the 'NO_Contactor' to the 'Emergency Off' coil. After the contact has been assigned, the<br />

cross-reference is applied online to the contact and the contact comb after clicking the left mouse<br />

button anywhere in the drawing field. Exit the Symbol Explorer with 'Cancel'.<br />

Hint<br />

This procedure can also be reversed. This means that a contact can<br />

be loaded first and a part number (from the database) can be<br />

assigned. As the part is assigned, the automatic process identifies<br />

and manages the contact arrangement even when the coil is not yet<br />

positioned on the drawing sheet.<br />

Cross-reference Navigator<br />

Now you can learn how to access the position a cross-reference is pointed to, quickly<br />

and easily.<br />

Let's use the contact comb of the contactor 'Feed forward' as an example. Note the<br />

cross-reference text at the left of the comb; this represents the position of the associated<br />

contact.<br />