<strong>Getting</strong> <strong>Started</strong><br />
Therefore you will only need to load a 'Dummy’ entry from the database, in order to set<br />
the dimensions of the mounting plate. This part has a preceding '.' (full stop) to exclude<br />
it from the material list.<br />
Click on 'Supplements' in the open 'Control Cabinet Manager' and select the<br />
database entry 'AE cabinet compact one door' (part number<br />
'.AE1060600'). Position the mounting plate to the co-ordinates 750,0/575,0 mm. Exit with<br />
'Abort + remove' and quit the 'Control Cabinet Manager'.<br />
Drawing Cable trays, top hat rails and collection<br />
bars<br />
92<br />
Now place the cable trays on the mounting plate. Select a cable tray via the<br />
adjacent symbol.<br />
The database selection opens again. Select 'Cable tray' with part number<br />
'KL25/60'. Ignore the activated text input field by pressing .<br />
Hint<br />
If you already know the length of the cable channel you can enter<br />
this into the input field.<br />
• Set the 1. vertical tray on the co-ordinates 762,5/837,5 mm and the end point<br />
at 762,5/300,0 mm. Close the opening symbol parameters.<br />
• Start the 2. vertical tray at 1312,5/837,5 mm, with the end point at<br />
1312,5/300,0 mm.<br />
• Place the 1. horizontal tray on the co-ordinates: 787,5/837,5 mm to<br />
1312,5/837,5 mm.<br />
• The 2. from 787,5/687,5 mm to 1312,5/687,5 mm.<br />
• The 3. from 787,5/512,5 mm to 1312,5/512,5 mm.<br />
• And the last from 787,5/387,5 mm to 1312,5/387,5 mm.<br />
The top hat rails are drawn in the same way as the cable channels.<br />
Load a top hat rail and select the database entry 'Top hat rail perforated'.<br />
Set the first co-ordinate at 787,5/762,5 mm and the end point at 1312,5/762,5 mm.<br />
Then place three more top hat rails, from 787,5/600,0 mm to 1312,5/600,0 mm,<br />
from 787,5/450,0 mm to 1312,5/450,0 mm and from 787,5/337,5 mm to<br />
1312,5/337,5 mm.