9 DESIGNING THE BUILDING Volume II<br />

Figure 9-31.<br />

House being constructed<br />

with a steel frame on<br />

wood piles<br />

9.4.4 Fire Safety Considerations<br />

Designing and constructing townhouses and low-rise multi-family coastal buildings to withstand natural<br />

hazards and meet the building code requirements for adequate fire separation presents some challenges.<br />

Although fire separation provisions of the 2012 IBC and 2012 IRC differ, they both require that the common<br />

walls between living units be constructed of materials that provide a minimum fire resistance rating. The<br />

intent is for units to be constructed so that if a fire occurs in one unit, the structural frame of that unit would<br />

collapse within itself and not affect either the structure or the fire resistance of adjacent units.<br />

For townhouse-like units, the common framing method is to use the front and rear walls for the exterior<br />

load-bearing walls so that firewalls can be placed between the units. Beams that are parallel to the front and<br />

rear exterior walls are typically used to provide support for these walls as well as the floor framing. Figure<br />

9-32 illustrates a framing system for a series of townhouses in which floor beams are perpendicular to the<br />

primary direction of flood forces. Design issues include the following:<br />

5. The floor support beams are parallel to the shore and perpendicular to the expected flow and may<br />

therefore create an obstruction during a greater-than-design flood event.<br />

6. The fire separation between townhouse units limits options for structural connections between units,<br />

making the transfer of lateral loads to the foundation more difficult to achieve.<br />

7. The exposed undersides of buildings elevated on an open foundation (e.g., pile, pier, post, column) must<br />

be protected with a fire-rated material. Typically, this is accomplished with use of fire-resistant gypsum<br />

board; however, gypsum board is not a flood-damage-resistant material. An alternative approach is<br />

to use other materials such as cement-fiber board (with appropriate fire rating), which has a greater<br />

resistance to damage from floodwaters, and fire retardant treated wood. Other alternative materials or<br />

methods of protection that are flood-damage-resistant may be required in order to meet the competing<br />

demands of flood- and fire-resistance.<br />

9-36 COASTAL CONSTRUCTION MANUAL