Volume II RETROFITTING BUILDINGS FOR NATURAL HAZARDS 15<br />

15.4.2.1 Basic Mitigation Package<br />

COASTAL CONSTRUCTION MANUAL<br />

Figure 15-15.<br />

Wind Retrofit Mitigation<br />

Packages<br />

SOURCE: <strong>FEMA</strong> P-804<br />

The Basic Mitigation Package focuses on securing the roof system and improving the water intrusion resistance<br />

of the home. Figures 15-16 and 15-17 show two retrofits that fall into the Basic Mitigation Package. One of<br />

the first decisions to make when implementing the Basic Mitigation Package is whether to use Option 1 or<br />

Option 2. The evaluation will identify whether the roof covering needs to be replaced (see Section 3.1.1 of<br />

<strong>FEMA</strong> P-804 for more information).<br />

If the home is located in a wind-borne debris region, the opening protection measures described in the<br />

Intermediate Mitigation Package should be performed for the Basic Mitigation Package in addition to the<br />

other retrofits. The opening protection measures include installing an approved impact-resistant covering or<br />

component at each exterior window, skylight, entry door, and garage door opening.<br />

<strong>FEMA</strong> P-804 includes procedures, material specifications, and fastening schedules (when applicable)<br />

to facilitate implementation of the Basic Mitigation Package. Alternative methods and materials are also<br />

discussed to facilitate installation for a variety of as-built conditions.<br />