Volume II Designing the builDing envelope 11<br />

Exterior Insulating Finishing System<br />

EIFS can be applied over steel-frame, wood-frame, concrete, or<br />

CMU<br />

construction. An EIFS assembly is composed of several<br />

note<br />

types<br />

of materials, as illustrated in Figure 11-18. Some of the<br />

When a window or door assembly<br />

layers<br />

are adhered to one another, and one or more of the layers<br />

is installed in an EIFS wall<br />

is<br />

typically<br />

mechanically attached to the wall. If mechanical assembly, sealant between the<br />

fasteners<br />

are used, they need to be correctly located, of the window or door frame and the<br />

proper<br />

type and size, and of sufficient number (based on design EIFS should be applied to the<br />

loads<br />

and tested resistance). Most EIFS failures are caused by EIFS base coat. After sealant<br />

application, the top coat is<br />

an<br />

inadequate<br />

number of fasteners or an inadequate amount of<br />

then applied. The top coat is<br />

adhesive.<br />

somewhat porous; if sealant is<br />

applied to it, water can migrate<br />

At<br />

the<br />

residence shown in Figure 11-19, the synthetic stucco was between the top and base coats<br />

installed<br />

over molded expanded polystyrene (MEPS) insulation and escape past the sealant.<br />

that<br />

was adhered to gypsum board that was mechanically<br />

attached<br />

to wood studs. Essentially all of the gypsum board<br />

blew<br />

off (the boards typically pulled over the fasteners).<br />

The failure was initiated by detachment of the<br />

gypsum<br />

board or by stud blow off. Some of the gypsum board on the interior side of the studs was also blown<br />

off.<br />

Also, two windows were broken by debris.<br />

Figure 11-18.<br />

Typical EIFS assemblies<br />

COASTAL CONSTRUCTION MANUAL<br />