Fasten converter retaining bracket 22.110<br />

to the converter and transmission housing<br />

with 2 screws 22.120 and 22.130.<br />

(Tightening torques: see Chapter 1.5)<br />

Important:<br />

The converter retaining screw must not<br />

be too long (recommended length<br />

14 mm) or else the converter will be<br />

damaged and the converter clutch will<br />

malfunction.<br />

3.9.3 Installing breather cover and<br />

protective transit caps<br />

Press breather cover 01.630 into the<br />

breather.<br />

After this, attach all transit plugs/caps:<br />

1 Transit plug for selector shaft<br />

1 Plug 27.340/118 on EGS wiring harness<br />

2 Plug 01.640 for cooler connection<br />

3.9/8<br />

CD<br />

5 HP 19 FL © ZF Getriebe GmbH Saarbrücken<br />

99240<br />

99241<br />

00/08/01